Summary of Contents for AN Series

Page 1: ......

Page 2: ...nce diagram 3 Preparation before test 4 Operation of peak hold release and tracking button 4 Adjustment of indicator dial 4 Hand held testing 5 Peak hold and load tracking pointer 5 Accessories 5 Actual dimensions 6 Maintenance 7 Packaging checklist 7 ...

Page 3: ...CIFICATION Model SL 2 SL 10 SL 20 SL 50 SL 100 Range 2lb 10lb 20lb 50lb 100lb Graduation 0 01lb 0 05lb 0 1lb 0 2lb 0 5lb Accuracy 2 Stroke 10mm Work temperature 20 10ºC Carry temperature 27ºC 70ºC Relative humidity 15 80 RH ...

Page 4: ...page 3 2 REFERENCE DIAGRAM ...

Page 5: ...hange to PEAK Turn button clockwise until the PEAK position is reached c After Testing After testing is complete return the button to the PEAK position this helps to extend the life of the internal mechanism a Ensure that the indicator dial is rotated to 0 for the start of the test This can be achieved by turning the indicator dial clockwise or anti clockwise depending on the initial position b Wh...

Page 6: ...e load applied to the gauge PEAK The pointer will stop at the maximum load applied during the course the test Press the release button to return the gauge to 0 The unit is supplied with a range of standard accessories Should your application require a special fixture please contact your Mecmesin supplier who will be pleased to review your requirement 7 PEAK HOLD AND LOAD TRACKING POINTER 8 ACCESSO...

Page 7: ...page 6 9 ACTUAL DIMENSIONS Please note that if you wish to use the gauge with a Mecmesin test stand then an additional bracket will be required This will increase the dimension by 13 5mm approximately ...

Page 8: ...mounting bracket Part No 408 471 F99 c Do not apply load exceeding the rated capacity of the gauge d Do not use your gauge in a place of low or high temperature and humidity please see specification table for recommended operating environment 11 PACKAGING CHECKLIST Name Quantity Analogue Gauge 1 Extension Rod 1 Hook 1 Compression Plate 1 Cone Point 1 Inverted Chisel 1 Chisel Point 1 M3 Screws 4 Us...

Page 9: ...page 8 ...

Page 10: ...page 9 ...

Page 11: ...page 10 ...

Page 12: ... Copse Business Park Slinfold West Sussex RH13 0SZ England General Enquiries t 44 0 1403 799979 f 44 0 1403 799975 Service Calibration t 44 0 1403 799920 f 44 0 1403 799925 i www mecmesin com e info mecmesin com DISTRIBUTOR STAMP ...