background image

Mobile Hand Wash Station

REVISION: 07/2020  |  page 12 of 16                                                                                        INSTALLATION & OPERATING MANUAL

 

Chapter 7.   OPERATING INSTRUCTIONS 

7.1  Models BSX-MHB-HCW and BSX-MHB-HCW-T 
Important!  Following installation, the time flow valve needs to be primed to  

remove air from the hose.  
Actuate time flow valve by compressing and releasing by foot. At 3 bar water  

pressure, each actuation will provide a run time of 8 to 12 seconds. Repeat  

as necessary. 

 

 

 

 

 

7.2  Model BSX-MHB-X 
Important!  Following installation, or following water container refill, the manual  

foot pump needs to be primed to remove air from the hose.  
Actuate manual foot pump by compressing and releasing. Each compression will  

deliver water to the spout. Repeat as necessary. 

7.2.1  Remove empty water feed container. Lift out feed hose.  

7.2.2  Lift flexible waste hose out of waste container. 

7.2.3  Remove waste container from unit. Ensure container screw cap is replaced. Dispose of waste water. 

NOTE:

 Be careful to manoeuvre the containers around the flexible waste fittings to prevent damage. 

NOTE:

 Waste water is dirty and must be disposed of responsibly. 

7.2.4  Ensure empty waste container is replaced into the LHS of the unit with neck facing front and screw cap 

removed. Reinsert flexible waste hose into neck of the container.  

7.2.5  Once refilled, replace water hose into fresh water container and reinsert into the RHS of the unit with the 

neck of the container facing the rear.  

NOTE:

 Be careful to manoeuvre the containers around the flexible waste fittings to prevent damage. 

NOTE:

 When transporting full water containers ensure screw cap is fitted. 

7.2.6  Following each water container refill manual foot pump needs to be primed to remove air from the hose.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Basix BSX-MHB-HCW

Page 1: ...the spread of germs by hand Hand washing is the number one prevention against the spread of viruses bacteria and other pathogens Good hand washing habits can be encouraged with the right equipment installed in the correct position Spout with water saving diffuser Our BSX MHB X model will provide approx 223 hand wash cycles from 1x 12 5L water container If the alternative ultra water saving diffuse...

Page 2: ...Mobile Hand Wash Station REVISION 07 2020 page 2 of 16 INSTALLATION OPERATING MANUAL ...

Page 3: ...ve Manual mixer valve Spout fitted with water saving diffuser 2x removable castors Splashback with integrated grab handle Front hinged door with turn thumb latch to access services and internal lower storage shelf Built in slots in side panels for hanging bin and towel dispenser options Built in cut outs with removable covers to the rear and side panels for waste and water services connection Time...

Page 4: ...hese instructions carefully Correct installation and operation will provide optimum performance and a longer life 3 2 SAFETY INSTRUCTIONS 3 3 PRODUCT CONFORMITY 3 3 1 The mobile hand wash station range is supplied to the marketplace having been produced under the control of our comprehensive BSI ISO 9001 2015 Quality Management System certificate FS 616985 3 2 1 Children should be supervised while...

Page 5: ...uilt in hatches on both sides with removable panels for waste and water services connection G Door H turn thumb latch I Internal shelf for water waste containers Internal storage shelf J Protective edge trim K 2x Castors L Reinforced PVC Hoses Stainless steel braided hose M Manual foot pump valve Time flow foot valve N Barbed hose connection Manual mixing valve Thermostatic mixing valve O Reinforc...

Page 6: ...n REVISION 07 2020 page 6 of 16 INSTALLATION OPERATING MANUAL Chapter 6 INSTALLATION INSTRUCTIONS 6 1 Equipment needed 6 2 Install spout use spanner to tighten 6 3 Lay splashback on a flat surface Remove screws and put aside ...

Page 7: ... Station INSTALLATION OPERATING MANUAL REVISION 07 2020 page 7 of 16 6 4 Slide frames to align top 2 holes with splashback holes With holes aligned fit screws 6 5 Splashback is now ready to be fitted onto the main body ...

Page 8: ...N OPERATING MANUAL 6 6 Slide fitted splashback onto main body as shown Ensure bowl splashback sits behind main body splashback Once the splashback is placed into position and holes align fit screws Splashback is now installed 6 7 If needed fit castors Bowl splashback ...

Page 9: ...ffuser For the BSX MHB X model the water saving diffuser can be swapped for the ULTRA water saving diffuser HOW TO REPLACE DIFFUSER Manually unscrew the diffuser remove the washer and the insert diffuser Replace with the alternative diffuser ensuring that the existing washer is re used when fitting 6 10 For models BSX MHB HCW and BSX MHB HCW T final connections to mains water feed and waste 1 inch...

Page 10: ...alve However if desired this can be installed at the inlet end of the water supply 6 12 2 Installation NOTE Install manual mixing valve with adjustable valves facing the installer Recommended pressure range 1 5 3 Bar Connect the cold water supply to the inlet on the LHS as viewed from the view in picture above Connect the hot water supply to the inlet on the RHS as viewed from the view in picture ...

Page 11: ...he foot plate However if desired this can be installed at the inlet end of the water supply 6 13 2 Installation Recommended dynamic pressure 1 5 bar HW supply temperature 55 85 C CW supply temperature 5 20 C Balance the HW CW pressure P 1 bar PREMIX NANO can be installed in any position Connect the hot water supply to the inlet with a red marker and the cold water to the inlet with a blue marker 6...

Page 12: ...ainer Lift out feed hose 7 2 2 Lift flexible waste hose out of waste container 7 2 3 Remove waste container from unit Ensure container screw cap is replaced Dispose of waste water NOTE Be careful to manoeuvre the containers around the flexible waste fittings to prevent damage NOTE Waste water is dirty and must be disposed of responsibly 7 2 4 Ensure empty waste container is replaced into the LHS o...

Page 13: ...roduct is used For general cleaning use soap or a mild detergent and water on a sponge Rinse with clean water and wipe dry if necessary Avoid abrasive cleaning products such as scourers The mobile basin range must be installed and operated in compliance with the supplied instructions The use of suitable PPE such as gloves is recommended when cleaning or maintaining this product Do not use abrasive...

Page 14: ...Mobile Hand Wash Station REVISION 07 2020 page 14 of 16 INSTALLATION OPERATING MANUAL NOTES ...

Page 15: ...Mobile Hand Wash Station INSTALLATION OPERATING MANUAL REVISION 07 2020 page 15 of 16 ...

Page 16: ...ssociates Material and information included are correct at time of print Intending buyers and users must satisfy themselves as to the suitability and safety of the products for their particular purposes and duties Dimensions shown in mm unless otherwise stated Product accreditation may not apply to all products in the relevant range Please contact Mechline to confirm Unless otherwise stated all pr...

Reviews: