Mobile Hand Wash Station
REVISION: 07/2020 | page 10 of 16 INSTALLATION & OPERATING MANUAL
6.12 MANUAL MIXING VALVE – supplied with model BSX-MHB-HCW
6.12.1 Technical features
•
Balanced water pressure supplies required. Pressure range 1.5-3 Bar. Hold and cold pressure should be
no more than 1bar flow differential.
•
Joint seals to be made using PTFE tape ONLY.
•
NO JOINTING COMPOUNDS to be used under any circumstances.
•
The preferred location for the manual mixing valve is next to the time flow foot valve. However, if
desired, this can be installed at the inlet end of the water supply.
6.12.2 Installation
NOTE:
Install manual mixing valve with adjustable valves facing the installer.
•
Recommended pressure range 1.5-3 Bar.
•
Connect the cold water supply to the inlet on the LHS as viewed from the view in picture above.
•
Connect the hot water supply to the inlet on the RHS as viewed from the view in picture above.
6.12.3 Calibrating the temperature
After installation turn the adjustments screws using a 3mm Allen key until the desired water temperature
delivery to the spout is achieved. Turn clock-wise to close the valve and anti-clockwise to open the valve.
INPUT
COLD
INPUT
HOT
Adjustment screws