11
COMBI 787
Oil-hydraulic underground operator
for swinging gates
COMBI 787
ON THE LEFT GATE
COMBI 787
ON THE RIGHT GATE
LOCKING THE OPERATING ARM
Fasten the operating arm by the ring and screw,
tightening very hard.
Operating arm
Combi 787 left
Details of the lever system Combi 787 left
Gate
manual
release
Plate connecting
the operating arms
Driving arm tted onto
the Combi 787 shaft
Arm connected to the
gate release shoe
4
FITTING THE ARM CONNECTION PLATE
Fit the connection plate into the holes of the two arms.
5
ADJUSTMENT OF THE OPENING AND CLOSING GATE STOPS (if case no ground tting is allowed).
6
Grease
ATTENTION: THE MANUFACTURING COMPANY RECOMMENDS TO INSTALL OPENING AND CLOSING
GATE STOPS PREFERABLY ON GROUND. IN CASES WHERE THESE CANNOT BE FITTED, IT IS POSSIBLE
TO MOUNT GATE STOPS INSIDE THE MOTOR ENCLOSURE AND ADJUST THEM AS DESCRIBED BELOW.
!
Adjustment screw
CLOSING gate stop:
close the gate, then
adjust the screw and
tighten the locking nut
Adjustment screw
OPENING gate stop:
open the gate to the
required open position,
then adjust the screw
and tighten the
locking nut