Page 16
Mcro 26 - Operator’s Manual
March 2019
Secton 7 - Operatng Instructons and Functon Tests
Test Drive and Braking
Press and hold the Function Enable Switch on the control handle.
Slowly move the control handle forward/downward until the machine begins to move, then return
the handle to the center position.
Result:
The machine should move forward, in the direction of the steering wheels, then
come to a stop.
Regardless of if the Function Enable Switch is pressed or released, if no machine movement
is made in 10 seconds then the current selection of Drive will time-out.
Release then press the Function Enable Switch to reactivate selected function.
Press and hold the Function Enable Switch on the control handle.
Slowly move the control handle rearward/upward until the machine begins to move, then return
the handle to the center position.
Result:
The machine should move rearward, in the direction of the platform entry, then come
to a stop.
Regardless of if the Function Enable Switch is pressed or released, if no machine movement
is made in 10 seconds then the current selection of Drive will time-out.
Release then press the Function Enable Switch to reactivate selected function.
Note:
The brakes must be able to hold the machine on any slope it is able to climb.
Test Limited Drive Speed
Press the lift function select button.
Press the Function Enable Switch. Raise the platform approximately 6.6 ft / 2 m from the ground.
Result:
The pothole guards should deploy.
Press the drive function select switch.
Press and hold the Function Enable Switch on the control handle.
Slowly move the control handle to the full drive position.
Result:
The maximum achievable drive speed with the platform raised should not exceed 27
seconds over 20 ft (6.1 m)
If the drive speed with the platform raised exceeds 27 seconds over 20 ft (6.1 m),
immediately tag and remove the machine from service.
1.
2.
•
•
•
3.
4.
•
•
•
1.
2.
•
3.
4.
5.
•
•