Gripping

position

Gripping

position

Gripping

position

Gripping

position

Prior to maintenance and servicing of the unit, turn off the power and unplug the 

plug.

1. Surface cleaning 

Clean  the  surface  of  the  unit  with  wet  soft  cloth.  Do  not  use  chemical  solvents  such  as 

alcohol  and  gasoline;  otherwise,  the  surface  of  the  air-conditioner  may  be  damaged  and 

even the whole unit may be damaged. 

2. Cleaning of the filter frame and filter mesh 

Clean the filter mesh once every two weeks. If the filter frame and filter mesh are clogged 

with dust, the function of the air-conditioner may decrease 

2.1 Cleaning of the filter frame and filter mesh 

  1). Grip the gripping position of the evaporator filter frame and the condenser filter frame and 

take out the filter frame gently in the direction shown by the arrow (as shown in Figure 13).                    

2). Grip the gripping position of the evaporator filter mesh and condenser filter mesh and take 

out the filter mesh gently in the direction shown by the arrow (as shown in Figure 14). 

Note: when taking out the filter frame or filter mesh, the force shall be applied evenly to avoid 

twisting or damage of the filter frame or filter mesh. Be sure to take out the filter frame first 

and then take out the filter mesh. 

Figure 13                                                              Figure 14 

3).  Put  the  evaporator  filter  frame,  condenser  filter  frame,  evaporator  filter  mesh,  and 

condenser filter mesh into warm water (about 40

) to which neutral cleaner is added for 

cleaning and then dry them in the shade (as shown in Figure 15). 

      Note: 1. Do not damage the mesh fabric on the filter frame and filter mesh. 

Figure 15 

2.2 Installation of the filter frame and filter mesh 

Special note: be sure to install the filter mesh first and then install the filter frame. 

1

To install the evaporator filter mesh and condenser filter mesh, point the back end of the filter 

mesh toward the socket and then push the filter mesh evenly and gently into the socket.               

Note: 1. Install the filter mesh in the reverse order of removal. The filter mesh must be 

installed into place; otherwise, the filter frame may not be installed into place. 

            2. Install the filter mesh gently so as not to damage it. 

Summary of Contents for CAD-E0930 PR1D

Page 1: ...Page 1 16 User Manual CAD E0930 PR1D Portable Air conditioner...

Page 2: ...3 Function Description 5 Features and Parts 5 Installation 6 Control Setting 9 Remote Conrtol 11 Water Drainage Methods 12 Maintenance 13 End of Season Storage 15 Handling of the Unit 15 Troubleshoot...

Page 3: ...stumbling over it or the plug from being pulled out Do not insert any object into the air inlet outlet of the air conditioner Be sure to keep the air inlet outlet of the air conditioner unblocked Whe...

Page 4: ...ating functions The speed of the fan is adjustable between high fan speed and low fan speed the temperature setting range is 17 300 C and various protection functions such as 24h timed ON OFF setting...

Page 5: ...ting lever 18 Evaporator filter frame 6 Caster 19 Radiating fine mesh 7 Horizontal louvre connecting lever 20 Condenser filter mesh 8 Main vertical louver 21 Condenser filter frame 9 Front shell 22 Ba...

Page 6: ...to clip the snap joint of the C shape buckle of the back shell successfully through the guide of the slide way of the back shell as shown in Figure 2 Note 1 Do not rotate the C shape buckle of the hea...

Page 7: ...of the window sealing board assembly 2 Half open the window and mount the window sealing board assembly onto the window either vertically or horizontally as shown in Figure 5 and 6 3 Pull apart the p...

Page 8: ...be free from significant greater than 45 flexure and the heat exhaust hose shall be ventilated properly Figure 8 Figure 9 Important notes The exhaust hose is 280mm 1500mm long and this length is deter...

Page 9: ...Sleep Press this button to select sleep mode 4 Timer When turn off the unit press this button to set the time of turn on when turn on the unit press this button to set the time of turn off 5 Up Press...

Page 10: ...water turn off the power of the unit and then unplug the power plug Note move the unit carefully to avoid spillage of water in the water tray at the bottom of the unit 2 Put the vessel that holds wate...

Page 11: ...et Figure 12 3 Connect the drain hose to the WC or outdoor Note 1 The drain hose must be installed when there is not water in the baseplate 2 When operating in the cooling mode to ensure the water for...

Page 12: ...ection shown by the arrow as shown in Figure 14 Note when taking out the filter frame or filter mesh the force shall be applied evenly to avoid twisting or damage of the filter frame or filter mesh Be...

Page 13: ...area of this unit with wringed wet soft cloth Note the wet soft cloth must be wringed out Do not drip water into the unit 3 If the remote control needs to be put back into the remote control storage...

Page 14: ...C shape buckle of the heat exhaust hose by hand pull the C shape buckle outward evenly rotate the C shape buckle of the heat exhaust hose clockwise once the buckle is separated from the snap position...

Page 15: ...y reduce noise The compressor does not work Initiation of overheat protection Wait 3 minutes until the temperature decreases and then turn on the unit Too long a distance The remote control does not p...

Page 16: ...nical parameters of the models refer to the nameplate on the product s Disposal do not store waste products with other non classified wastes Such wastes shall be stored separately for other special pu...

Page 17: ...ay To Friday 8 30am to 6 00pm Imported Distributed by FIMACO SDN BHD 110749 V Website www mec com my 8 2 WISMA FIAMMA No 20 Jalan 7A 62A Bandar Manjalara 52200 Kuala Lumpur Malaysia Tel 603 6279 8888...

Reviews: