![Mec 5492RT Operator'S Manual Download Page 32](http://html1.mh-extra.com/html/mec/5492rt/5492rt_operators-manual_1758677032.webp)
Page 28
92RT Scssor Lfts - Operator’s Manual
July 2020
Secton 10 - Machne Inspectons and Mantenance
Quarterly Inspection Checklist
This checklist must be used at quarterly intervals or every 300 hours
of machine use, whichever occurs first����� Failure to do so could result in
death or serious injury�����
Scheduled Maintenance Inspections should be conducted by qualified service technicians only.
Photocopy this page for reuse. Keep inspections records up to date. Record and report all
discrepancies to your supervisor.
Model Number
Serial Number
Hour Meter Reading
Initial
Description
Perform all checks listed on Prestart/Monthly Inspection.
Check the operation speeds to ensure they are within specified limits (see Specifications).
Check the emergency lowering system.
Clean and lubricate all push button switches with dry lubricant and ensure that the switches operate
freely in all positions.
Check the tightness of the platform frame and the linkage pins.
Check the overall platform and guardrail component stability.
Check the electrical mounting and hardware connections for security.
Check the king pins for excessive play.
Additional maintenance requirements for severe conditions
Initial
Description
Replace hydraulic filter element (under normal conditions replace every six [6] months).
DATE
INSPECTED BY