![Mec 5492RT Operator'S Manual Download Page 18](http://html1.mh-extra.com/html/mec/5492rt/5492rt_operators-manual_1758677018.webp)
Page 14
92RT Scssor Lfts - Operator’s Manual
July 2020
Secton 6 - Functon Tests and Operatng Instructons
ART_3035
Lower Control Box:
Turn key switch to BASE.
•
Diesel Engine
ART_3212
Flip switch to the top position to start the engine and then the switch will
return to ON position.
Cold Start:
Flip the switch to ON position then wait as indicated in the
Preheat table before flipping switch to top position.
Preheat Table
Ambient Temperature
Preheat Time
Above 50°F (10°C)
5 Seconds
50°F to 23°F (10°C to –5°C)
10 Seconds
Below 50°F (–5°C)
20 Seconds
20 Seconds = Limit of Continuous Use
•
•
Starting Engine from Upper Control Box
ART_3038
Upper Control Box:
Turn the Key Switch to PLATFORM.
•
Diesel Engine
ART_3212
Upper Control Box:
Hold switch in upper position until engine starts.
Release when engine starts then the switch will return to ON position.
Cold Start:
Flip the switch to ON position then wait as indicated in the
Preheat table before flipping switch to top position.
Preheat Table
Ambient Temperature
Preheat Time
Above 50°F (10°C)
5 Seconds
50°F to 23°F (10°C to –5°C)
10 Seconds
Below 50°F (–5°C)
20 Seconds
20 Seconds = Limit of Continuous Use
•
•
Base Controls Operation and Test