![Meatest M921 User Manual Download Page 62](http://html.mh-extra.com/html/meatest/m921/m921_user-manual_1758449062.webp)
Electromagnetic Flowmeter M921
MEATEST
62
Operation manual
7.2.3
Sensor
In the table below are the dimensions of the sensor for compact version. In case of remote version add 120
millimetres to dimension “A” for cable gland and cable. Flanges in DIN version meet standard EN1092.
Flanges in ANSI version meet requirements of ANSI B 16.5 standard.
DN (mm)
PN (bar)
D (mm)
A (mm)
L (mm)
Weight (kg)
15
16
95
145
200
3
20
16
105
150
200
3,5
25
16
115
155
200
4
32
16
140
165
200
5
40
16
150
175
200
5
50
16
165
185
200
7
65
16
185
200
200
8,5
80
16
200
215
200
10
100
16
220
235
250
13
125
16
250
265
250
17
150
16
285
295
300
22
200
16
340
355
350
31
250
10
395
435
450
44
300
10
445
485
500
57
350
10
505
535
550
72
400
10
565
580
600
95
500
10
670
695
600
120
600
10
780
800
600
160
700
10
895
900
700
230
800
10
1015
1010
800
330
Table 16 : Dimensions and weights – DIN flanges