background image

19

 

Chapter 4 

Specifications 

Typical for 25 °C unless otherwise specified.  

Specifications in 

italic text

 are guaranteed by design. 

Analog voltage output 

Table 1. Analog voltage output specifications 

Parameter 

Conditions 

Specifications 

Digital to Analog converter 

DAC8554 

Number of channels 

(Note 1) 

Resolution 

16 bits 

Output ranges 

Calibrated 

±10 V, 0 to 10 V  

Software configurable 

Un-calibrated 

±10.2 V, -0.04 to 10.08 V 

Software configurable 

Output transient 

±10 V to (0 to 10 V) or 

(0 to 10 V) to ±10 V range 
selection. 

(Note 2) 

Duration: 5 uS typ. 

Amplitude: 5V p-p typ. 

Host PC is reset, powered on, 
suspended or a reset command is 
issued to device. 

(Note 3) 

Duration: 2 S typ. 

Amplitude: 2V p-p typ. 

Initial power on 

Duration: 50 mS typ. 

Amplitude: 5V peak typ. 

Differential non-linearity 

(Note 4) 

Calibrated 

±1.25 LSB typ. 

-2 LSB to +1 LSB max.

Un-calibrated 

±0.25 LSB typ. 

±1 LSB max. 

Output current 

VOUTx pins 

±3.5 mA typ. 

Output short-circuit protection 

VOUTx connected to AGND 

Indefinite 

Output coupling 

DC 

Power on and reset state 

DACs cleared to zero-scale: 0 V, ±50 mV typ. 

Output range: 0-10 V 

Output noise 

0 to 10 V range 

14.95 µVrms typ. 

±10 V range 

31.67 µVrms typ. 

Settling time 

to 1 LSB accuracy 

25 µS typ. 

Slew rate 

0 to 10 V range 

1.20 V/µS typ. 

±10 V range 

1.20 V/µS typ. 

Throughput 

Single-channel 

100 Hz max., system dependent 

Multi-channel 

100 Hz/#ch max., system dependent 

Note 1: 

Each of the four DAC8554 outputs controls a VOUTx and IOUTx channel-pair simultaneously. 
So, for example, when writing to channel VOUT0, the associated IOUT0 channel will also be 
updated. Conversely, when writing to channel IOUT0, the associated VOUT0 channel is also 
updated. Unused VOUTx and IOUTx output channels should be left disconnected. 

Summary of Contents for USB-3100 Series

Page 1: ......

Page 2: ...USB 3102 USB based Analog Output User s Guide Document Revision 4A March 2009 Copyright 2009 Measurement Computing Corporation...

Page 3: ...in any form by any means electronic mechanical by photocopying recording or otherwise without the prior written permission of Measurement Computing Corporation Notice Measurement Computing Corporation...

Page 4: ...11 Chapter 3 Functional Details 12 External components 12 USB connector 12 Status LED 12 Power LED 12 Screw terminal banks 13 Analog voltage output terminals VOUT0 to VOUT3 14 Analog current output te...

Page 5: ...USB 3102 User s Guide 5 Environmental 24 Mechanical 24 Main connector and pin out 24 Declaration of Conformity 25...

Page 6: ...of objects on a screen such as buttons text boxes and check boxes italic text Italic text is used for the names of manuals and help topic titles and to emphasize a word or phrase Where to find more in...

Page 7: ...rent channel pair simultaneously You set the voltage output range of each DAC channel independently with software for either bipolar unipolar or current The bipolar range is 10 V the unipolar range is...

Page 8: ...nnels 16 bit DIO 8 channels Analog Current Output 4 channels 16 bit 4 channel Quad 4 Full speed USB 2 0 Compliant Interface Figure 2 USB 3102 block diagram Software features For information on the fea...

Page 9: ...Start pdf This booklet supplies a brief description of the software you received with your USB 3102 and information regarding installation of that software Please read this booklet completely before...

Page 10: ...ows Update or download the update from www microsoft com downloads details aspx familyid 733dd867 56a0 4956 b7fe e85b688b7f86 displaylang en For more information refer to the Microsoft Knowledge Base...

Page 11: ...ion disconnect the USB cable from the computer and then reconnect it This should restore communication and the power LED should turn back on Calibrating the USB 3102 The USB 3102 is shipped fully cali...

Page 12: ...ower and communication to the USB 3102 The voltage supplied through the USB connector is system dependent and may be less than 5 V No external power supply is required Status LED The Status LED indica...

Page 13: ...nalog voltage output connections VOUT0 VOUT2 Two analog current output connections IOUT0 IOUT2 Four analog ground connections AGND Eight digital I O connections DIO0 to DIO7 Screw terminal pins 29 56...

Page 14: ...s associated current output is also updated Each channel pair can be updated individually or simultaneously Leave each pair of unused voltage and current outputs disconnected Analog current output ter...

Page 15: ...y IOUTn 2 IOUTn IOUTn 1 IOUTn 1 IOUTn 2 IOUTn Figure 6 Typical analog current output circuit Refer to the manufacturer s information for the device being controlled for additional details Current Test...

Page 16: ...d digital I O techniques refer to the Guide to Signal Connections available on our web site at www mccdaq com pdfs DAQ Signal Connections pdf Digital I O control terminal DIO CTL for pull up down conf...

Page 17: ...al to configure the SYNCLD mode as master or slave On power up and reset the SYNCLD pin is set to slave mode input Refer to the USB 3100 Series section in the Universal Library User s Guide for inform...

Page 18: ...channels on each device are updated simultaneously An example of a master slave configuration is shown here S Slave PMD 1608F Master device Slave device SYNCLD pin terminal pin 49 D A LOAD signal Conf...

Page 19: ...ferential non linearity Note 4 Calibrated 1 25 LSB typ 2 LSB to 1 LSB max Un calibrated 0 25 LSB typ 1 LSB max Output current VOUTx pins 3 5 mA typ Output short circuit protection VOUTx connected to A...

Page 20: ...22 0 Table 3 Absolute accuracy components specifications calibrated output Range of reading Offset mV Temp drift C Absolute accuracy at FS mV 10 V 0 0183 1 831 0 00055 3 661 0 to 10 V 0 0183 0 915 0...

Page 21: ...alog output calibration specifications Parameter Conditions Specifications Recommended warm up time 15 minutes min On board precision reference DC level 5 000 V 1 mV max Tempco 10 ppm C max Long term...

Page 22: ...00 Ohm series resistor Note 10 When SYNCLD is in input mode the analog outputs may either be updated immediately or when a positive edge is seen on the SYNCLD pin this is under software control Howeve...

Page 23: ...the USB 3102 which includes up to 10 mA for the status LED This does not include any potential loading of the digital I O bits 5V user terminal ITEST or the VOUTx IOUTx outputs Note 12 Output voltage...

Page 24: ...in connector specifications Connector type Screw terminal Wire gauge range 16 AWG to 30 AWG Pin Signal Name Pin Signal Name 1 VOUT0 29 VOUT1 2 IOUT0 30 IOUT1 3 VOUT2 31 VOUT3 4 IOUT2 32 IOUT3 5 AGND 3...

Page 25: ...the following conditions must be met The host computer peripheral equipment power sources and expansion hardware must be CE compliant Equipment must be operated in a controlled electromagnetic enviro...

Page 26: ...ion 10 Commerce Way Norton Massachusetts 02766 508 946 5100 Fax 508 946 9500 E mail info mccdaq com www mccdaq com NI Hungary Kft H 4031 Debrecen H tar t 1 A Hungary Phone 36 52 515400 Fax 36 52 51541...