5.7 Label information
The label placed on top of the module contains the following information:
Type Code :
see table in chapter 2.2
HW/SW Code :
internal Hardware/Software-Versions
Serial No.:
YYWWNNNNN
Serial Number consists of nine digits. YY shows the year of production (2011=11), WW the week of
the production and NNNNN the unique number for identification and traceability.
5.8 Cable and configuration
The inclinometer is delivered with a cable of approximately 1 m length.
Type of cable:
LiYCY 6x0.14mm
2
Conductor resistance:
131 Ohm/km
Capacity:
90pF/m at 1kHz
Following configuration/cable color scheme is in use:
Cable
color
Name
Description
Type
White
Vcc
Positive power supply
Supply, Input
Yellow
GND
Ground
Supply, Input
Brown
Out X
Voltage output X
Output
Green
Out Y
Voltage output Y
Output
Grey
RxD
RS 232 input
Input
Pink
TxD
RS 232 output
Output