Instruction Manual
DPG-Series Inclinometer
MEAS Deutschland GmbH
www.meas-spec.com
phone: +49-(0)231-9740-0
Hauert 13, D-44227 Dortmund, Germany
14 of 15
fax: +49-(0)231-9740-20
July 2015
7
Qualification Testing
7.1 Standards
The sensor NS-xx/DPG2-xxx complies with:
•
IEC/EN 60068-2-2
High Temperature Storage
Ta= 85°C, medium : air, 1000h
•
IEC/EN 60068-2-78
High Humidity
Ta= 85°C , RH= 85%, 1000h
•
IEC/EN 60068-2-27
Mechanical shock test
A=30g, t=11ms, halfsine, 50 cycles per axis
•
IEC/EN 60068-2-6
Vibration loading
10 to 150 Hz, 2.5mm amplitude, 5g const. acceleration,
1 octave/minute, 20 cycles per axis
•
IEC/EN 60068-2-14
Thermo shock
T
High
=85°C ,T
Low
=-40°C,medium:air-air,T
dwell
: 15min,
T
change
: 30sec,100 cycles
•
IEC/EN 61000-6-2
Interference resistance industry
•
IEC/EN 61000-6-4
Emitted interference industry
7.2 Periodical Testing
The periodical testing is done every 3 years in terms of a product audit.
7.3 Material Testing
All materials used in the process will be released by checking the corresponding supplier certificates
when available. A regular material analysis from an independent laboratory will not be scheduled.