Page 1: ...MEADE INSTRUMENTS CORP PROFESSIONAL WEATHER STATION WITH REMOTE CONTROL TE923W USER MANUAL...

Page 2: ...Personal Computer 21 Navigating through the modes 22 Customizing your Weather Station 25 Operations and Window Selection 25 Pressure and Weather Forecast Window 25 UV Window 28 Time Window 29 Manual S...

Page 3: ...One Rain Gauge remote rain sensor transmitter TS906 One Anemometer remote wind sensor transmitter TS805 One UV ultraviolet sensor remote ultraviolet sensor transmitter TS704 One Five Channel Temperatu...

Page 4: ...Shaped Sensor holder Circular Ground Stand Stake Base Wall Mounting Base Thermo Hygrometer Sensor Rain Gauge consists of Funnel shaped top with battery compartment Rain Gauge bucket Bucket see saw mec...

Page 5: ...d to the main unit wirelessly with the operating range in the open area from 100 feet 30 meters for anemometer and rain gauge and up to 328 feet 100 meters for thermo hygrometer and UV sensors Remote...

Page 6: ...for each remote weather sensor separately Transmission range may be affected by trees metal structures and electronic appliances The main unit must be placed indoors The effective operating range may...

Page 7: ...der on the flat surface E UV SENSOR LID Covers UV sensor and seals battery compartment F BATTERY COMPARTMENT Holds two AA size batteries G BATTERY COMPARTMENT DOOR Covers two AA size batteries Assembl...

Page 8: ...in the opening Secure the sensor in a location with a maximum sun exposure throughout the day Stake Snap the sharp stake end onto the metal bar and secure with the screws provided Insert the other en...

Page 9: ...it Flashes twice when battery power is low B BATTERY COMPARTMENT Holds two AA size batteries C RESET Resets all readings requires small paper clip D CHANNEL SWITCH Selects the desired channel from 1 t...

Page 10: ...place the thermo hygrometer sensor above the natural surfaces such as a grassy lawn Avoid placing the thermo hygrometer sensor near sources of heat such as chimneys and heating elements Avoid any area...

Page 11: ...stallation level Non corrosive protective screen A Rain gauge bucket Contains mechanical components B Knob Secures the top on the rain gauge bucket C Rain gauge bucket feet Secures the rain gauge on i...

Page 12: ...e bucket is level check if the bubble center is inside the built in leveler Place the protective screen over the top to protect the rain gauge from the debris Mount the rain gauge in place using mount...

Page 13: ...d wind direction data transmission to the main unit via 433 MHz signal Operating range 100 feet 30 meters Wall or pole mount A WIND VANE Indicates wind direction B WIND CUPS Measures wind speed C ANEM...

Page 14: ...nt yet as you need to make sure that the anemometer sends the signal to the main unit 0 0 mph will appear on the main unit s wind window if the signal was sent and received successfully Aligning This...

Page 15: ...justment of time and date Calendar displaying date with month and day in 6 languages English German French Italian Spanish and Dutch Sunrise set calculation for over 100 pre programmed world cities in...

Page 16: ...trol functions If the main unit operates solely on the battery power the auto backlight control and handheld remote control functions will be disabled When placing the main unit on the table or other...

Page 17: ...Window and a default sunset sunrise time in the Sunrise Sunset Window If pressure and altitude are not configured during this time the Weather Station will self calibrate in a few minutes and show th...

Page 18: ...available mode clockwise Decreases parameters Recalls all remote sensors signals when depressed and held for 5 seconds C SET Rotates display for current mode If depressed and held enters into the prog...

Page 19: ...n unit K LIGHT SENSOR AUTO ON OFF Toggles the light sensor to automatic on or off setting L SENSITIVITY HIGH LOW Adjusts the light sensor sensitivity M AC DC ADAPTOR INPUT Connects main unit to the po...

Page 20: ...the pressure and altitude sea level indoor outdoor temperature and humidity readings remote sensors readings etc Many settings can be changed or customized to your preference after the display has st...

Page 21: ...on on the computer desktop You may customize software screen by selecting the weather parameters to be displayed units for these weather parameters location and other user definable elements When dete...

Page 22: ...flashing Press UP button on the main unit or the handheld remote control to cycle through the modes clockwise or DOWN anti clockwise Pressure and Weather Forecast Window Displays Moon phase Weather fo...

Page 23: ...ndow Displays Sunrise and sunset times Longitude and Latitude Temperature and Humidity Window Displays Temperature and humidity readings for indoor and selected channel Comfort level indication Dew po...

Page 24: ...t day yesterday last week and last month Rainfall alert Remote rain gauge battery status Wind Window Displays Wind Chill temperature Temperature at place of anemometer Wind direction Wind speed Wind g...

Page 25: ...istory Pressure is displayed inHg English hPa mBar scientific or mmHg metric Altitude is displayed in meters or feet The weather station is designed to measure local pressure and calculate the other t...

Page 26: ...or mmHg millimeters of mercury Press SET button to confirm and store selection Then unit will advance to the altitude unit selection Press UP or DOWN arrow button selecting the altitude unit in feet...

Page 27: ...button entering the sea level pressure display When the SEA LEVEL is displayed press HISTORY repeatedly viewing the sea level pressure history for the past 24 hours in 1 hour intervals If no buttons...

Page 28: ...artly Cloudy Cloudy or Light Rain or Heavy Rain Unstable Weather Snow Note The weather forecast accuracy is approximately 70 Display shows forecasted not current conditions The SUNNY icon indicates cl...

Page 29: ...g Units for UV Display MED h or UVI In UV Mode press and hold SET to convert units between MED h and UVI Time Window Manual Settings The main unit can be manually set to display the time calendar or U...

Page 30: ...ode closest to your area by pressing UP or DOWN arrow buttons Refer to P for a list of available codes Press SET button to confirm the selection and enter the year calendar and time setting Press the...

Page 31: ...he City code Hour and Minutes with the Seconds Month with the day and a year Hour and Minutes for UTC Coordinated Universal Time Activating or deactivating alarms Press the ALARM CHART button to displ...

Page 32: ...ted during the daylight hours The radio controlled clock will search for an alternate station that receives the atomic time signal from the NIST Atomic clock in Boulder Colorado The WWVB tower icon on...

Page 33: ...the closest city code is selected the main unit will automatically generate all of the correct data for specified location If you cannot find the closest city code or would like to enter your specifi...

Page 34: ...ime and sunrise sunset times Calendar and sunrise sunset times Calendar and longitude latitude Viewing Sunrise Sunset Times for Different Dates In Sunrise Sunset Window press MEMORY button until the d...

Page 35: ...he main unit Note The temperature alarms have a 0 5 C deviation to prevent them from sounding due to small temperature fluctuations that are close to the set alarm value This means that after the temp...

Page 36: ...Dew point and relative humidity Programming Temperature in Celsius or Fahrenheit In Temperature and Humidity Window press and hold SET button to toggle the temperature in Celsius C or Fahrenheit F Act...

Page 37: ...orresponding remote sensor signal received successfully No signals received for over 15 minutes All Remote Sensor Signals Search Activation The main unit can be manually activated to search for the si...

Page 38: ...DOWN to deactivate Programming Daily Rainfall Alarm In the Rain Window press ALARM CHART button to display the rainfall alarm Press and hold ALARM CHART button until the ALARM HI will flash Set the d...

Page 39: ...emory In the Wind Window press and hold MEMORY button to reset all wind statistics Activating or Deactivating Alarms In the Wind Window press ALARM CHART button to recall Current wind speed Wind speed...

Page 40: ...the main unit to avoid losing any data Remove the battery compartment door on the back and replace all batteries Do not mix old and new batteries Replace the battery compartment door Changing Batterie...

Page 41: ...l weather reports The weather data may vary considerably due to different environmental conditions and placement Check the placement tips included in this manual to site your weather sensors in the be...

Page 42: ...xcessive force shock dust temperature or humidity which may result in malfunctions shorter lifespan damaged batteries and damaged parts Do not tamper with the product s internal components Doing so wi...

Page 43: ...P 7 SU Pittsburgh Pa PIT 5 SU Houston Tex HOU 6 SU Portland Ore PDX 8 SU Indianapolis Ind IND 5 NO San Antonio Tex SAT 6 SU Jacksonville Fla JAX 5 SU San Diego Calif SAN 8 SU Las Vegas Nev LAS 8 SU Sa...

Page 44: ...Paris France PAR 1 SE Lima Peru LIM 5 NO Perth Australia PER 8 NO Lisbon Portugal LIS 0 SE Prague Czech PRG 1 SE Liverpool England LPL 0 SE Rangoon Myanmar RGN 6 5 NO London England LON 0 SE Reykjav k...

Page 45: ...al standard time Specifications Radio Frequency 433 MHz RF Reception range 100 328 feet 30 100 m Barometric Pressure Measuring Range 14 75 inHg to 32 44 inHg 500 HPa to 1100HPa 374 5 mmHg to 823 8 mmH...

Page 46: ...0 to 360 Resolution 22 5 Accuracy 11 25 Starting Threshold 3mph 4 8 Km h Transmitting interval 33 seconds Wind Speed Range 0 to 100 mph 160 Km h 86 897 Knots Resolution 0 1mph 0 16 Km h Accuracy 2mph...

Page 47: ...162 H x 35 D mm Remote Thermo Hygrometer 2 37 L x 4 H x 1 D inches 60 L x 101 H x 25 D mm Remote UV unit 2 58 L x 4 45 H x 2 58 D inches 65 5 L x 113 H x 65 5 D mm Remote Anemometer 19 16 L x 19 16 H...

Page 48: ...bble Irvine CA 92618 Telephone No 1 949 451 1450 declare that the product Product No TE923W Product Name Professional Weather Station with Remote Control Manufacturer Hideki Electronics Ltd Address Un...

Page 49: ...e and to obtain a Return Goods Authorization RGA Returns without a return authorization will be refused Please retain your original receipt as you may be asked to provide a copy for proof of purchase...