Technical data
(in battery operation or U
B
= 8…26V DC in the nominal temperature range)
Size
Value
Unit
Accuracy class
Analogue
Digital
0,1
0,05
%
%
Inputs
Measurement range
±1 (JP1 on 1 with 5V sensor supply)
±2 or ±3.5 per software
(JP1 on 2 with 2,5V sensor supply)
mV/V
mV/V
Connectible full bridge
4 x 350
Ohm
Bridge supply voltage
2,5 / 5
V
Input impedance
>20 (300pF)
MOhm
Common mode rejection
DC
100Hz
>120
>100
dB
dB
Analogue input 1)
Input voltage range
Input resistance
0…10
56
V
kOhm
Accuracy
Linearity deviation
<0,02
% of unit
Influence of temperature on
the zero point per 10K
Measurement range 1mV/V:
<0.4 type 0.2
Measurement range 2mV/V:
<0.2 type 0.1
% of unit
% of unit
Influence of temperature on
the measurement sensitivity
per 10K referring to the
measured value
Analogue output
Display / digital
< 0,1; type. 0,05
<0,01; type. 0,005
%
%
Resolution
Peak value
RMS
>30000 parts
>150000 parts
Output
Analogue output filter
-3dB cut-off frequency, Bessel,
2. order
Digital output filter
- 3dB cut-off frequency
Digital output measuring
rate
3.5; 260; 1700 (can be switched using software)
0.06..1700
0..3750
Hz
Hz
Hz
Analogue output
Source resistance
-5...+5
47
V
Ohm
Control cables
High level: 3.4 (active high)
ME-Meßsysteme GmbH
Neuendorfstr. 18a
Tel.: +49 3302 78620 60
Mail: [email protected]
16761 Hennigsdorf
Fax: +49 3302 78620 69
Web: www.me-systeme.de
21