Adjustment of Input Sensitivity
8
Instruction Manual
Input sensitivity can be adjusted by relocating the jumper. Input sensitivity for position 1
is given in the type designation. With position 5 amplification can be adjusted
continously by the trimmer "TR".
Position
Amplification
factor
Output voltage at sensitivity
option 2 mV/V
Output voltage at sensitivity
option 3.5 mV/V
1
1
±5 volts at
±2 mV/V
±5 volts at
±3.5 mV/V
2
2
±5 volts at
±1 mV/V
±10 volts at
±2 mV/V
±5 volts at
±1.75 mV/V
±10 volts at
±3.5 mV/V
3
4
±5 volts at
±0.5 mV/V
±10 volts at
±1 mV/V
±5 volts at
±0.875 mV/V
±10 volts at
±1.75 mV/V
4
10
±5 volts at
±0.2 mV/V
±10 volts at
±0.4 mV/V
±5 volts at
±0.35 mV/V
±10 volts at
±0.7 mV/V
5
1...10
±5 volts at
±0.2...2 mV/V
±10 volts at
±0.4 ...2 mV/V
±5 volts at
±0.35...3.5 mV/V
±10 volts at
±0.7 ...3.5 mV/V
TR