Opera 240 System Manual
Page 54
Analogue phones
Compatibility of some analogue phones with MDS Opera systems:
ULYTEL II
PHONE
WITH
MESSAGE
WAITING
SIEMENS
EUROSET
2010
SIEMENS
EUROSET
2015
SIEMENS
GIGASET
4010
CLASSIC
SIEMENS
EIRCOM
4012
SIEMENS
EIRCOM
5012
COLOUR
SIEMENS
GIGASET
C 150
SIEMENS
EIRCOM
4012
MICRO
Last Number
Redial
Yes
Yes
Yes
Yes
Yes
Time Break
Recall (transfer,
etc)
Yes
Yes
Yes
Yes
Yes
Rings with a
different Internal
and External
Ring Cadence
Yes
No *
Yes
No*
Yes
Message
Waiting audible
indication
Yes
Yes
Yes
Yes
Yes
Message
Waiting visual
indication
No
Not
applicable
Not
applicable
Not
applicable
Yes
Caller Display
(CLI)
No
No
No
Yes
Yes
Programmable
keys can be
Programmed as
MDS PABX
function keys
Yes**
Yes
Yes
N/A
N/A
N/A
N/A
N/A
* Does not differentiate between Internal and External ring cadence. Rings with one cadence
only.
**It is necessary to insert a Pause after Recall when programming function keys.
A
A
A
p
p
p
p
p
p
e
e
e
n
n
n
d
d
d
i
ii
x
x
x
I
II
V
V
V
M
M
M
i
ii
s
s
s
c
c
c
e
e
e
l
ll
l
ll
a
a
a
n
n
n
e
e
e
o
o
o
u
u
u
s
s
s
t
tt
i
ii
m
m
m
e
e
e
r
rr
s
s
s
e
e
e
t
tt
t
tt
i
ii
n
n
n
g
g
g
s
s
s
No
TIMER
Default
New Setting
Maximum
Minimum
1
Transfer Timeout
30 secs
3 mins
5 secs
2
Parked Call Timeout
3 mins
15 mins
10 secs
3
Forward No Answer Timeout
20 secs
3 mins
5 secs
4
Normal Disconnect Timer
20 secs
1 min
0 secs
5
Handsfree Disconnect Timer
3 secs
1 min
0 secs
6
Pause Timer
2 secs
1 min
0 secs
7
Maximum Voice Message Length
90 secs
180 secs
0 secs
8
Browser Timeout
15 mins
15 mins
30 secs
9
Phone Menu Timeout
60 secs
3 mins
15 secs
10
Call Back Timer 1
10 secs
15 mins
0 secs
11
Call Back Timer 2
20 secs
15 mins
0 secs
12
Call Back Timer 3
60 mins
4 hours
1 min
13
Roaming PIN Timer
30 secs
15 mins
0 secs
14
Hotline Timer
10 secs
60 secs
0 secs
15
Internet Disconnect Timer
3 mins
999 secs
1 secs
16
Trunk To Trunk Timer
2 mins
999 secs
10 secs
17
Trunk Line Supervision
90 msecs
999 msecs
60 msecs
Summary of Contents for Opera 240
Page 1: ...Opera 240 System Manual...