ICE FOG

 

Q

TM

 

User Guide, Revision A/d, May 2017 

8 / 16

 

SETTING UP 

WARNING: 

 

When not in use ALWAYS switch off the power switch located on the back panel, or 
unplug the generator. 

 

Never install above people. 

 

These  Fog  Generators  must  be  installed  in  an  upright  position  on  a  stable  and  level 
surface. 

 

Do not operate at less than 2 meters (6.5 ft.) from people. 

 

Use in a well ventilated area. 

 

Maximum Operating Pressure: 414 kPa / 4.1 bar / 60 psi 

 

LIQUID

 

&

 

GAS

 

REQUIREMENTS 

 

 

WARNING 

In  the  European  Community  the  gas  cylinder  and  regulator  must  be 
compliant with the Pressure Vessel Directive.   
In  North  America  the  gas  cylinder  must  be  manufactured,  inspected  and 
tested  in  accordance  with  U.S.  Department  of  Transportation  (DOT)  3AL 
and Transport Canada (TC) 3ALM requirements.

 

 

 

WARNING 

Only  use  low  pressure  refrigerated  liquid  Carbon  Dioxide  (CO

2

)  Dewar 

container.  The  recommended  pressure  should  be  1500  kPa  (225  psi)  ± 
10%.

 

  

 

CAUTION 

To prevent gas leak and drop of pressure, ALWAYS use a neoprene washer 
when connecting the regulator to the cylinder

 

 

 
The  CO

2

  gas  is  used  as  a  propellant  when  generating  Fog.  Output  pressure  can  be 

adjusted  by  mean  of  the  CO

gas  regulator  that  you  will  find  in  the  back  panel  of  the 

generator. 
 

Summary of Contents for ICE FOG Q

Page 1: ...E IN CAN A D A F A B R IQU AU CA N A D A 10301 avenue Pelletier Montr al Qu bec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com ICE FOG Q TM Low Fo...

Page 2: ...ICE FOG QTM User Guide Revision A d May 2017 2 16 Intentionally left blank...

Page 3: ...well as the MDG Low Fog Fluid We hope it will bring you long hours of satisfaction This product is available in many versions to satisfy the needs of our professional users PLEASE READ THE FOLLOWING...

Page 4: ...types of electronic fail safe systems are designed to protect against over and under heating conditions and against component failure The temperature is maintained within a narrow margin the HEAT yell...

Page 5: ...indicates that the liquid CO2 solenoid valve is on Fog Output Delay Delay of 3 to 30 seconds Allowing to cool down the cold chamber of the Generator Fog Output adjustment Pressure regulator Gauge Max...

Page 6: ...Fog switch with a Green LED indicator Power switch with the Red LED HEAT yellow LED indicator 1 The LED turns on and off from time to time to indicate the control of temperature 2 The LED will start b...

Page 7: ...d May 2017 7 16 Optional Accessories DMX M35AX Optional 2 Channel DMX Interface IF35 RCT Optional Remote Control Timer Refrigerated Low pressure Liquid Carbone Dioxide L CO2 Container Dewar 230 Litres...

Page 8: ...ylinder and regulator must be compliant with the Pressure Vessel Directive In North America the gas cylinder must be manufactured inspected and tested in accordance with U S Department of Transportati...

Page 9: ...nerator CAUTION DISCONNECT UNIT BEFORE ADDING FOG FLUID DEPRESSURIZE THE FLUID RESERVOIR BY TURNING OFF THE PRESSURE SWITCH LOCATED ON THE BACK PANEL OF THE GENERATOR To fill the fluid reservoir unscr...

Page 10: ...he start of the heating cycle which will last approximately 10 minutes When the temperature reaches a pre adjusted level called the READY level indicated by a green LED the HEAT yellow LED will turn o...

Page 11: ...ed Always turn off the fog emission Wait for the purge cycle to complete Power off the Fog generator by switching off the MAIN POWER SWITCH or by removing the MAIN POWER If not use for a long period A...

Page 12: ...180 L 48 US gallon Canister DEWAR 70 minutes Warm up time maximum 8 minutes Fluid type MDG Low Fog Fluid M S D S available on request Operating voltage 208 VAC 1 or 230 VAC 50 60 Hz Power consumption...

Page 13: ...ICE FOG QTM User Guide Revision A d May 2017 13 16 TECHNICAL DIMENSIONS...

Page 14: ...MDG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines responsibility for...

Page 15: ...ICE FOG QTM User Guide Revision A d May 2017 15 16 DECLARATION OF CONFORMITY...

Page 16: ...ICE FOG QTM User Guide Revision A d May 2017 16 16 NOTE...

Reviews: