eMINI fogger
User Guide, Rev: A/a, April 2020
14 / 28
O
PERATING INSTRUCTIONS
The
MDG
eMINI
fogger can be controlled either locally, with the keyboard, via DMX (
see DMX control and
RDM Control
). This paragraph focuses on
local control
.
Starting Procedures
Powered up the fogger, the control program configures the Input/Output and loads the configuration
parameters, saved in the EEPROM memory.
At this point, the
MDG
eMINI
switches to stand-by mode, and most of the electronic controls are off.
When the fogger is manually switched to
«UNIT ON»
mode («UNIT
ON»), the program starts the heating
cycle («STATE = % HEAT»), which will last approximately 7 minutes.
When the temperature reaches its operating level, the
eMINI
Fogger is ready to produce fog («STATE =
READY»).
NOTES:
Always check that the fog fluid hose and pumps are primed prior using the MDG eMINI fogger.
This is particular critical after you have refilled the fog fluid bottle, or if you have not used the fogger during
a long period.
To prime the
eMINI
fogger, do a fog burst of approximately 10 sec.
Fog Production
•
Normal Mode
The amount of the fog emission can be controlled by adjusting the fog output («CONTROL
OUTPUT»),
while the emission is controlled with the Fog menu set to ON («CONTROL
FOG
ON»).
•
Burst Mode
When the
fog
menu is toggle to
ON
, the
MDG
eMINI
fogger
will produce fog at very high output
during a period corresponding to the
burst
duration («CONTROL
BURST DUR»), in 1/10
th
of seconds
When the
burst
of fog is finished, the user will need to reset the
fog
menu to
OFF
(«CONTROL
FOG
OFF») to be able to restart a new burst.
During a fog burst, switching
fog
menu to
OFF
will abort the running fog burst.
The
MDG
eMINI
fogger will produce fog as long as the control parameters are within specifications, and
the fog fluid bottle filled.
Summary of Contents for eMINI
Page 2: ...eMINI fogger User Guide Rev A a April 2020 2 28 Intentionally left blank...
Page 25: ...eMINI fogger User Guide Rev A a April 2020 25 28 DIMENSIONS...
Page 27: ...eMINI fogger User Guide Rev A a April 2020 27 28 DECLARATION OF CONFORMITY...
Page 28: ...eMINI fogger User Guide Rev A a April 2020 28 28 NOTES...