Trouble Shooting
Electrical Trouble Shooting
Symptom
Possible Cause
Remedy
No 12 volt power
Main Isolator in off Position
Turn on main isolator
Flat battery
Charge battery
Faulty battery
Replace
Main circuit breaker tripped
Reset main circuit breaker
Loose battery terminals
Tighten terminals
Damaged wiring
Find and repair/replace
Battery not Charging
Faulty Battery
Have battery tested and replace if faulty
No mains power
Indicated by charger not turned on. Check mains power, if charger still
doesn’t switch on
the charger may be faulty and you should contact the dealer for warran
-
ty or replacement
Faulty Charger
A charger fault will be indicated by fast flashing on the charger control
panel (Projecta
Intelli-Charge). Contact your dealer for warranty or replacement.
Charger has overheated
Indicated by OTP on LCD screen and fast flashing. Ensure adequate
ventilation around
charger and allow to cool. Do not store items around the electronics.
(Projecta Intelli-Charge)
Lights or plugs not
working
Tripped circuit breaker
Reset breaker
Poor connection
find and rectify
Circuit switch off
Check control panel and switch on
No power to fridge
Indicators or parking
lights not working
Poor connection at trailer plug
Check and clean plug contacts. If pins are closed up use a knife to sepa
-
rate the split in the pins being sure not to widen too far. The gap should
be even along the length of the pin.
Inverter not powering
Poor connection
Check 12v connections are tight
Main 12v switch is off
Check main rotary switch on control panel
Flat battery
Charge battery
200A main circuit breaker
If no other 12v is available check the main 200A breaker with a multime
-
ter or test light
150A breaker to Inverter
check 150A breaker to inverter using a multimeter or test light
No Inverter Output
See Inverter trouble shooting
page
Circuit breaker tripping
during use
Overloading
Check amperage draw from appliance
Faulty Applience
Check appliance and rectify
Battery not charging
from anderson plug
Faulty Connection at plug
Check plug ensuring connections are firm
50A circuit breaker tripping
Check there are no shorts and check circuit breaker with multimeter or
test light
BMS
Check BMS is correctly set and operating (see manual page )
Summary of Contents for XT10E 2021
Page 37: ...www marketdirect com au Ph 1300 494 494 33...
Page 40: ...www marketdirect com au Ph 1300 494 494 36 12 Volt Main Circuit Diagram COMING SOON...
Page 41: ...www marketdirect com au Ph 1300 494 494 37 12 Volt Switch Circuit COMING SOON...
Page 63: ...www marketdirect com au Ph 1300 494 494 59 Trip Name Date Km Start Km Finish Cumulative Km...
Page 65: ...www marketdirect com au Ph 1300 494 494 61 Hub Assembly...
Page 66: ...www marketdirect com au Ph 1300 494 494 62 Trailing Arm Bushes...
Page 90: ...www marketdirect com au Ph 1300 494 494 86 Video Tutorials COMING SOON...