www.mdcusa.com
Ph: 833 632 8721
67
AquaGo comfort / AquaGo comfort plus
Problem
Potential Cause
Resolution
The yellow status
LED 3 is off al
-
though an oper
-
ating mode was
selected.
Power swtich is OFF
Switch ON the appliance at the POWER switch.
Power supply to the appliance is
switched off
Switch on the power supply to the appliance.
Power supply was interrupted
Reset by switching OFF at the control panel, waiting
2 seconds and then switching on again.
If none of the measures in the troubleshooting chart proves successful, please contact your dealer,
the Truma Service Center at 1-855-558-7862 or one of our authorized service partners.
Water Supply
Symptoms
Cause
Remedy
Water drips from the P&T
safety valve.
– Water pressure to high.
– Lime or dirt under the P&T safety
valve seat.
Check water pressure (max. 400 kPa), use a
pressure reducer when connected to central
water supply.
Allow the appliance to cool and then slowly
raise the test lever (Fig. 2a – 4a) to flush the
water system and attempt to force dirt or
foreign matter out of the P&T safety valve
seat.
Replace P&T safety valve. This must be
performed only by a certified service
technician.
When opening the cold water
tap, hot water comes out.
– Hot water flows back through the
cold water supply.
-Fit a non-return valve in the cold water
supply (refer to installation instructions
“Water connection”).
-Non return valve faulty
Water Pumps
The water pump in your Robson XTT are located under the seat on the driver’s side of your camper behind the wheel
arch. The pumps when switched on are activated by the release of pressure at the tap and will pump water continuously
until the tap is turned off and pressure restored. Should the pumps activate while the taps is turned off this could
indicate a leak and require investigation and rectification.
Switch Supply Tanks
To switch between the supply tanks, locate the valved beneath the camper underneath the driver’s side near the hot
water system.
Summary of Contents for ROBSON XTT
Page 71: ...www mdcusa com Ph 833 632 8721 71 Electrical Diagram...
Page 72: ...www mdcusa com Ph 833 632 8721 72...
Page 73: ...www mdcusa com Ph 833 632 8721 73 Hub Assembly...
Page 74: ...www mdcusa com Ph 833 632 8721 74 Trailing Arms and Bushes...
Page 98: ...www mdcusa com Ph 833 632 8721 98 Trip Name Date Miles Start Miles Finish Cumulative Miles...