21
RBM
APPENDIX 1 - Contact Configuration
Value
Use
Comment
0
Feedback Returns turnout address
Feedback Returns turnout address
1
Switch switching command Switches the turnout
address when the contact closes
Switch switching command Switches the
turnout address when the contact
closes
2
Feedback level control Returns the turnout
address by level
Feedback level control Returns the
turnout address by level
3
Switch level control Switches soft level-
dependent (open / close
➔
right / left)
Switch level control Switches soft level-
dependent (open / close
➔
right / left)
4
Feedback dependent on direction Signals switch
address dependent on direction (2 contact inputs
➔
Returns the last connected one)
Feedback dependent on direction
Signals switch address dependent on
direction (2 contact inputs
➔
Returns
the last connected one)
5
Switch depending on direction Switches on
depending on direction (2 contact inputs
➔
Switches last address)
Switch depending on direction Switches
on depending on direction (2 contact
inputs
➔
Switches last address)
6
Feedback module Returns the switch address
Feedback module Returns the switch
address
+128
no track monitoring
Does not monitor for the contact input
whether a valid DCC signal is present
but always switches the output.