14. ELECTRICAL SYSTEM MALFUNCTIONS
BATTERY OVERTEMPERATURE
BATTERY
Indications:
Red
140F
160F
battery 160
°
F warning indicator ON.
Conditions:
Battery overtemperature at 160
°
F (71
°
C) or above.
Procedures:
e
Battery switch: OFF
e
Land as soon as possible
NOTE
:
No further flights are authorized until battery is inspected and cause of overtemp
corrected.
BATTERY
Indications:
Yellow
140F
160F
battery 140
°
F caution indicator ON.
Conditions:
Battery overtemperature at 140
°
F (60
°
C).
Procedures:
e
Battery switch: OFF
e
Battery must remain off line during remainder of flight.
NOTE
:
The Yellow battery 140°F light will go out after the battery has cooled to below
140°F (60°C). No further flights are authorized until battery is inspected and
cause of overtemp corrected.