Optional Equipment
Emergency Floats
FAA Approved
Revision 6
9
−
27
PART IV NORMAL
PROCEDURES
Checks Prior to Flight:
Check condition and security of stowed float package.
NOTE
:
Emergency floats with squib
−
actuated valve are identified by the word
‘‘SQUIB”
clearly visible on float cover.
Check pressure gauge in each float package. If the pressure vessel is at
70
°
F (21.1
°
C), the pressure should read 3000 to 3500 psig.
Indicated gauge pressure will increase (decrease) approximately as tabulated
below per 1
°
F (1
°
C) increase (decrease) in temperature of the pressure ves-
sel.
See Figure 1 to verify that pressure is adequate for the anticipated mini-
mum operating temperature.
Charge Pressure
Psig/
°
F
Psig/
°
C
3000
3100
3500
5.7
5.9
6.6
10.2
10.5
11.9
Set BATTERY−EXT switch in proper position (BATTERY when using ro-
torcraft battery. EXT when using an external power source).
Close emergency float circuit breaker.
Press−to−test. All four circuit indicator lamps should illuminate.
PART V
PERFORMANCE DATA
Hover Performance with Stowed Floats:
No change from that of the basic helicopter.
Height Velocity Diagram:
With floats stowed, Landing Height−Velocity Diagram is unchanged from
that of the basic helicopter.
Summary of Contents for MILVIZ MD530F
Page 1: ... MD530FModel R O T O R C R A F T F L I G H T M A N U A L REGISTRATION NO SERIAL NO i ...
Page 10: ...MV MD530F ROTORCRAFT FLIGHT MANUAL n 250 C20 2 10 ...
Page 42: ......
Page 65: ......
Page 100: ......
Page 103: ......
Page 196: ......
Page 219: ......
Page 222: ......
Page 242: ......
Page 244: ......
Page 257: ......
Page 265: ......
Page 277: ......
Page 283: ......
Page 304: ......
Page 322: ......