CSP
−
E
−
1
Emergency and
Malfunction Procedures
ROTORCRAFT FLIGHT MANUAL
MD 500E
(Model 369E)
Revision 14
3
−
13
FAA Approved
Conditions:
In flight
Procedures:
Land immediately
POWER ON APPROACH AND LANDING
WITHOUT DELAY
Air vents
VENTILATE CABIN AS NECESSARY
Twistgrip
CUTOFF
−
AS SOON AS HELICOPTER IS ON
GROUND
BAT/EXT switch
OFF
Passengers/crew
EVACUATE
IF UNABLE TO LAND IMMEDIATELY AND FIRE SOURCE
CAN BE IDENTIFIED:
Malfunctioning system
OFF
Fire extinguisher
USE AS NECESSARY
Cabin
VENTILATE
Land
AS SOON AS POSSIBLE
IF FIRE SOURCE IS UNKNOWN:
Cabin heat
OFF
Generator
OFF
All electrical circuits
(not required for safety of flight)
OFF
Cabin
VENTILATE
Land
AS SOON AS POSSIBLE