![MCZ Veld Use And Installation Download Page 7](http://html1.mh-extra.com/html/mcz/veld/veld_use-and-installation_1756399007.webp)
Chapter 2
USE AND MAINTENANCE MANUAL
page
7
Installation recommendations in compliance with UNI 10683
Technical dept. - All rights reserved by MCZ GROUP S.p.A. - Reproduction
prohibited
2.2.
THE OPERATING ENVIRONMENT
In the case of concurrent installation with other heating appliances,
provide the appropriate air inlets for each one (according to the
instructions for each appliance).
Installing the stove in a bedroom or bathroom is not
permitted, nor in any room where another heating
appliance is installed without an independent air
inflow.
It is forbidden to position the stove in rooms with an
explosive atmosphere.
The floor of the room where the stove is installed
must be suitably sized to withstand its weight.
2.2.1.
Safe distances
If particularly delicate objects are present, such as furniture, curtains or
sofas, increase the stove clearances substantially.
If the stove is positioned on a flammable floor, we
recommend you ensure it is suitably insulated.
Heat-sensitive or flammable objects and parts
cannot be stored near the stove; keep such objects
or parts at a minimum front clearance of 100 cm
from the outermost point of the appliance.
VELD Non-flammable
walls *
Flammable walls
*
A=15cm
B=20cm
A=20cm
B=30cm
20
c
m
m
in
.
30 cm.
* Leave an appropriate distance from the walls in any case in order to allow easier appliance maintenance.
A
B