4. INSTALLATION AND ASSEMBLY 

 

  

IMPORTANT! 
The stove must be installed and connected to the flue 

pipe by a specialised technician or by competent 

staff so that all local or national regulations are 

complied with and in all cases in accordance with the 

provisions of standard UNI 10683 REV. 

 
When you unwrap the stove and related frame, 

make sure that 

every part is in perfect

 

working order or check for any damage 

due to transport. 

If the stove is installed in a difficult to access place, 

the weight can be lightened by removing the internal elements making 

up the combustion chamber. 

We recommend you reposition each 

element correctly.

 

 

4.1. 

 

PREPARATION AND UNPACKING 

The Veld stove is delivered with three different packagings: 

 

one contains the stove (figure 1) 

 

one contains the ceramic parts (sides and fronts) figure 2 (the 

box containing the ceramic parts will be placed on top of the 

structure packaging) 

Open the package, remove the packaging straps and the two brackets 

(fig. 3) that secure the stove to the pallet. 
Remove the two screws (A) from the bracket at the bottom right and 

left of the stove. 
Then remove the other three screws (B) securing the bracket to the 

pallet and position the stove in the chosen location, making sure it 

complies with the applicable provisions. 

Only reposition the sides onto the stove after it has been 

positioned in the right place. 

 
 

 

 

A

A

B

B

B

BRACKE

Figure 1 - Veld stove packaging 

 

Figure 2 - Veld stove ceramic 

packaging 

Figure 3 - 

Removing the packaging 

screws (Veld stove) 

Summary of Contents for Veld

Page 1: ...0 USE AND INSTALLATION MANUAL EN NuTech Renewables Ltd Unit 11 Warrenpoint Enterprise Centre Newry Road Warrenpoint Co Down BT34 3LA Tel 44 28 417 53031 Email info nutechrenewables com www NuTechrenew...

Page 2: ...LUE PIPE 10 2 6 1 Flue pipe examples 11 2 7 CHIMNEY 12 3 DIMENSIONS AND TECHNICAL SPECIFICATIONS 13 3 1 VELD STOVE 13 3 1 1 Technical specifications 14 4 INSTALLATION AND ASSEMBLY 15 4 1 PREPARATION A...

Page 3: ...in the event of faults or if in doubt please contact your retailer who will provide all the necessary assistance Document revisions In order to improve the product and to update this document the Manu...

Page 4: ...ilation ducts If Oyster technology is not implemented Avoid having several operational flue ducts in the room or the proximity of a stair well and make sure that there are no appliances in adjacent co...

Page 5: ...tly or indirectly be caused to property or personal injury or harm to animals ensuing from failure to observe all the instructions provided herein and specifically concerning the warnings regarding in...

Page 6: ...al air inlet and that they are not used as a bedroom or bathroom or where there is no fire hazard such as garages timber storerooms warehouses of flammable materials observing under all circumstances...

Page 7: ...stove in rooms with an explosive atmosphere The floor of the room where the stove is installed must be suitably sized to withstand its weight 2 2 1 Safe distances If particularly delicate objects are...

Page 8: ...oes not reduce the minimum cross section be positioned in such a way as to not be obstructed the maximum length permitted for ducting is 6 m with two 90 elbows The stove must be connected to the exter...

Page 9: ...illes always feature an indication of the useful cross section in cm2 on one side When choosing the grille and hole size check that the useful cross section of the grille is larger or the same as the...

Page 10: ...fibre cement pipes is forbidden The smoke pipe must not cross rooms in which it is forbidden to install combustion appliances The use of counter sloping pipes is forbidden 2 6 FLUE PIPE The flue pipe...

Page 11: ...ngular cross section the ratio between the internal dimensions should be 1 5 The sections lengths of the flue pipe shown in the technical data table are guidelines for correct installation Any alterna...

Page 12: ...ze Steel flue pipe chimney with internal smoke deflector cone Allows excellent smoke disposal The chimney must Have an inner section equal to that of the flue Have a working outlet section of at least...

Page 13: ...age 13 Dimensions and technical specifications Technical dept All rights reserved by MCZ GROUP S p A Reproduction prohibited 3 DIMENSIONS AND TECHNICAL SPECIFICATIONS 3 1 VELD STOVE 218 267 5 8 0 1124...

Page 14: ...output Min KW 3 5 Kcal 3010 Efficiency 84 7 Heatable volume m3 151 40 172 35 201 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 240 C Particulate 30 mg Nm3 13 O2 17 mg MJ Smoke outlet 15 cm...

Page 15: ...n chamber We recommend you reposition each element correctly 4 1 PREPARATION AND UNPACKING The Veld stove is delivered with three different packagings one contains the stove figure 1 one contains the...

Page 16: ...of the structure and they can be installed as illustrated in the figure and adjusted with a screwdriver inserting it into the tip of the feet 4 3 CERAMIC CLADDING ASSEMBLY The installation of the cera...

Page 17: ...Chapter 4 USE AND MAINTENANCE MANUAL page 17 Installation and assembly Technical dept All rights reserved by MCZ GROUP S p A Reproduction prohibited G F SPINE H I D L E C C B A B PINS...

Page 18: ...smoke and paint smells If necessary touch up the paint with the spray can of the dedicated colour see Stove accessories Do not stand close to the stove and as mentioned air the room The smoke and pai...

Page 19: ...ot burn waste The gases produced by combustion resulting from the use of unsuitable fuel could damage the stove the flue pipe pollute and compromise your health 5 3 USING THE STOVE 5 3 1 FUEL LOADING...

Page 20: ...THE RIGHT The lever turned towards the right pos 1 is designed to bring a large quantity of primary air beneath the combustion chamber fire plane to allow rapid and effective ignition of the fire Fig...

Page 21: ...of wood Open the combustion air damper completely right hand lever Light the paper and if necessary keep the door open a few minutes until the combustion chamber and the flue pipe begin to warm up On...

Page 22: ...to contact with hot parts In the event of poor weather conditions for the operation of the stove low pressure external temperatures not particularly harsh windy day this may lead to inverse draught i...

Page 23: ...sable to handle the door carefully without slamming it or forcing it open or shut Since it is not a flexible element the glazing may break In addition this type of glazing does not shatter or burst an...

Page 24: ...hich the appliance should operate correctly have been reached and consequently we recommend the use of the quantity of fuel specified in the technical tables 6 1 6 Cleaning the flue pipe We recommend...

Page 25: ...MCZ GROUP S p A Via La Croce 8 33074 Vigonovo di Fontanafredda PN ITALY Telephone 39 0434 599599 PBX Fax 39 0434 599598 Internet www mcz it e mail mcz mcz it 8901142800 Rev 1 12 2011...

Reviews: