Warnings and guarantee terms 

Technical dept. - All rights reserved by MCZ GROUP S.p.A. - Reproduction 

prohibited 

 

1.3. 

 

GUARANTEE TERMS 

MCZ guarantees the product, 

with the exception of 

parts subject to normal wear specified 

below, for 

two years from the date of purchase, provided that 

proof of purchase is supplied in a document specifying 

the name of the retailer and the date the sale was 

made and that the completed guarantee certificate 

was sent within 8 days of said purchase. The product 

must also be installed and tested by a specialised 

fitter and in accordance with the detailed instructions 

provided in the instruction manual that accompanies 

the product. 
The guarantee covers the replacement or free repair 

of parts recognised as being faulty at source 

due to manufacturing defects. 

1.3.1. 

 

Guarantee limits 

The guarantee does not cover parts subject to normal 

wear, such as: 

seals, glazing, and all the 

removable parts of the combustion chamber. 

The parts replaced will be guaranteed for the 

remaining guarantee cover period starting from the 

original date of purchase of the product. 
 

 

The glazing in particular is 

guaranteed until an authorised MCZ 

fitter certifies that it is perfectly 

intact at the time of completion of 

installation.

 

 

1.3.2. 

 

Exclusions  

The guarantee does not cover all parts found to 

be faulty due to negligence or inappropriate 

use, incorrect maintenance, or installation not 

performed in compliance with MCZ's 

instructions (see relevant chapters in this use 

manual). 

 
MCZ will not be held liable for any damage which may 

- either directly or indirectly - be caused to property, 

or personal injury or harm to animals ensuing from 

failure to observe all the instructions provided herein 

and specifically concerning the warnings regarding 

installation, use and maintenance of the device. 
Please contact your retailer and/or local importer in 

the event of product failure. 
Damage caused by transport and/or handling are not 

covered by the guarantee. 
Reference must be made solely to the manual 

provided for product installation and use. 
 

The guarantee is not valid for damage caused by 

tampering with the device, atmospheric agents, 

natural disasters, electrical discharges, fires, faults in 

the electrical and plumbing system and caused by 

failure to perform maintenance or by incorrect 

maintenance in compliance with the Manufacturer's 

instructions. 
 

Service call 
Service calls must be made to the 

retailer, who will forward the call to 

the MCZ technical support 

department. 
MCZ cannot be held liable if the 

product and any of its accessories are 

used incorrectly or modified without 

authorisation. 

Only original MCZ spare parts must 

be used for replacements.  

 
 

1.4. 

 

IMPORTANT INFORMATION FOR 

CORRECT DISPOSAL OF THE PRODUCT 

IN ACCORDANCE WITH EC DIRECTIVE 

2002/96/EC 

.

 

 

At the end of its working life, the product must not be 

disposed of as urban waste. 

It must be taken to a special local authority 

differentiated waste collection centre or to a dealer 

providing this service. 

Disposing of a appliance separately avoids possible 

negative consequences for the environment and 

health deriving from inappropriate disposal and 

enables the constituent materials to be recovered to 

obtain significant savings in energy and resources.  

As a reminder of the need to dispose of appliances 

separately, the product is marked with a crossed-out 

wheeled dustbin. 

Summary of Contents for Veld

Page 1: ...0 USE AND INSTALLATION MANUAL EN NuTech Renewables Ltd Unit 11 Warrenpoint Enterprise Centre Newry Road Warrenpoint Co Down BT34 3LA Tel 44 28 417 53031 Email info nutechrenewables com www NuTechrenew...

Page 2: ...LUE PIPE 10 2 6 1 Flue pipe examples 11 2 7 CHIMNEY 12 3 DIMENSIONS AND TECHNICAL SPECIFICATIONS 13 3 1 VELD STOVE 13 3 1 1 Technical specifications 14 4 INSTALLATION AND ASSEMBLY 15 4 1 PREPARATION A...

Page 3: ...in the event of faults or if in doubt please contact your retailer who will provide all the necessary assistance Document revisions In order to improve the product and to update this document the Manu...

Page 4: ...ilation ducts If Oyster technology is not implemented Avoid having several operational flue ducts in the room or the proximity of a stair well and make sure that there are no appliances in adjacent co...

Page 5: ...tly or indirectly be caused to property or personal injury or harm to animals ensuing from failure to observe all the instructions provided herein and specifically concerning the warnings regarding in...

Page 6: ...al air inlet and that they are not used as a bedroom or bathroom or where there is no fire hazard such as garages timber storerooms warehouses of flammable materials observing under all circumstances...

Page 7: ...stove in rooms with an explosive atmosphere The floor of the room where the stove is installed must be suitably sized to withstand its weight 2 2 1 Safe distances If particularly delicate objects are...

Page 8: ...oes not reduce the minimum cross section be positioned in such a way as to not be obstructed the maximum length permitted for ducting is 6 m with two 90 elbows The stove must be connected to the exter...

Page 9: ...illes always feature an indication of the useful cross section in cm2 on one side When choosing the grille and hole size check that the useful cross section of the grille is larger or the same as the...

Page 10: ...fibre cement pipes is forbidden The smoke pipe must not cross rooms in which it is forbidden to install combustion appliances The use of counter sloping pipes is forbidden 2 6 FLUE PIPE The flue pipe...

Page 11: ...ngular cross section the ratio between the internal dimensions should be 1 5 The sections lengths of the flue pipe shown in the technical data table are guidelines for correct installation Any alterna...

Page 12: ...ze Steel flue pipe chimney with internal smoke deflector cone Allows excellent smoke disposal The chimney must Have an inner section equal to that of the flue Have a working outlet section of at least...

Page 13: ...age 13 Dimensions and technical specifications Technical dept All rights reserved by MCZ GROUP S p A Reproduction prohibited 3 DIMENSIONS AND TECHNICAL SPECIFICATIONS 3 1 VELD STOVE 218 267 5 8 0 1124...

Page 14: ...output Min KW 3 5 Kcal 3010 Efficiency 84 7 Heatable volume m3 151 40 172 35 201 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 240 C Particulate 30 mg Nm3 13 O2 17 mg MJ Smoke outlet 15 cm...

Page 15: ...n chamber We recommend you reposition each element correctly 4 1 PREPARATION AND UNPACKING The Veld stove is delivered with three different packagings one contains the stove figure 1 one contains the...

Page 16: ...of the structure and they can be installed as illustrated in the figure and adjusted with a screwdriver inserting it into the tip of the feet 4 3 CERAMIC CLADDING ASSEMBLY The installation of the cera...

Page 17: ...Chapter 4 USE AND MAINTENANCE MANUAL page 17 Installation and assembly Technical dept All rights reserved by MCZ GROUP S p A Reproduction prohibited G F SPINE H I D L E C C B A B PINS...

Page 18: ...smoke and paint smells If necessary touch up the paint with the spray can of the dedicated colour see Stove accessories Do not stand close to the stove and as mentioned air the room The smoke and pai...

Page 19: ...ot burn waste The gases produced by combustion resulting from the use of unsuitable fuel could damage the stove the flue pipe pollute and compromise your health 5 3 USING THE STOVE 5 3 1 FUEL LOADING...

Page 20: ...THE RIGHT The lever turned towards the right pos 1 is designed to bring a large quantity of primary air beneath the combustion chamber fire plane to allow rapid and effective ignition of the fire Fig...

Page 21: ...of wood Open the combustion air damper completely right hand lever Light the paper and if necessary keep the door open a few minutes until the combustion chamber and the flue pipe begin to warm up On...

Page 22: ...to contact with hot parts In the event of poor weather conditions for the operation of the stove low pressure external temperatures not particularly harsh windy day this may lead to inverse draught i...

Page 23: ...sable to handle the door carefully without slamming it or forcing it open or shut Since it is not a flexible element the glazing may break In addition this type of glazing does not shatter or burst an...

Page 24: ...hich the appliance should operate correctly have been reached and consequently we recommend the use of the quantity of fuel specified in the technical tables 6 1 6 Cleaning the flue pipe We recommend...