Air Intake Grille Installation
•
Before installed the air intake grille, make
sure the air filter is clip properly to the air
intake grille.
•
Install the air intake grille together with the air
filter to the front panel.
•
The grille can be fit in any direction, when
selecting direction, the ceiling design and
grille operability should be considered.
•
If the unit comes with ionizer filter (optional
item), make sure to fix the ionizer filter to the
air filter before installed the air intake grille.
•
Fix the ionizer filter to the air filter with the
black side on top and white side at bottom.
•
Carefully clip on the ionizer filter frame.
FRAME
(OPTIONAL ITEM)
IONIZER FILTER
(OPTIONAL ITEM)
FILTER
(STANDRAD ITEM)
Installation of Outdoor Unit
Preliminary Site Survey
•
A place protected from rain, direct sunlight and well-ventilated wherever practicable.
•
A place capable of carrying the weight of the outdoor unit and isolating noise and vibration.
•
A place where there are no obstruction of air flow into or out the unit.
•
Do not put any object which may block/reduce the air flow into or out the outdoor unit.
•
The location must not be susceptible to high concentration of dust, oil, salt or sulfide gas.
Outdoor Unit Installation
Install the outdoor unit firmly and horizontally. Maintain a space clearance from the obstruction as shown in below for the
purpose of servicing and air ventilation.
All Models
A
B
C
D
Minimum Distance
300 mm
1000 mm
300 mm
500 mm
CAUTION :
If the condensing unit is operated in an atmosphere containing oils(including machine oils),
salt(coastal area), sulphide gas(near hot spring, oil refinery plant), such substances may lead to
failure of the unit.
77
Summary of Contents for MCK 010C
Page 19: ...CK20B BR NC Curves CK15B BR NC Curves 18...
Page 20: ...CK30B BR NC Curves CK25B BR NC Curves 19...
Page 44: ...Outdoor Unit MLC030 040 050C CR M4LC030 040 050C CR 43...
Page 46: ...Indoor Unit Cooling Only Model MCK030A Outdoor Unit Model MLC030B 45...
Page 47: ...Indoor Unit Cooling Only Model MCK030A Outdoor Unit Model MLC M4LC030C 46...
Page 48: ...Indoor Unit Cooling Only Model MCK040A Outdoor Unit Model MLC035C 47...
Page 49: ...Indoor Unit Cooling Only Model MCK040 050A Outdoor Unit Model MLC M4LC040 050C 48...
Page 51: ...Indoor Unit Heat Pump Model MCK030AR Outdoor Unit Model MLC030BR 50...
Page 52: ...Indoor Unit Heat Pump Model MCK030AR M4LC030CR Outdoor Unit Model MLC 51...
Page 53: ...Indoor Unit Heat Pump Model MCK040AR Outdoor Unit Model MLC035CR 52...
Page 54: ...Indoor Unit Heat Pump Model MCK040 050AR Outdoor Unit Model MLC M4LC040 050CR 53...
Page 55: ...Indoor Unit Cooling Only Model MCK015B Outdoor Unit Model MLC015B 54...
Page 56: ...Indoor Unit Cooling Only Model MCK020 025B Outdoor Unit Model MLC020 025B 55...
Page 57: ...Indoor Unit Cooling Only Model MCK030B Outdoor Unit Model MLC030C 56...
Page 58: ...Indoor Unit Cooling Only Model MCK030B Outdoor Unit Model MLC030B 57...
Page 59: ...Indoor Unit Heat Pump Model MCK015BR Outdoor Unit Model MLC015BR 58...
Page 60: ...Indoor Unit Heat Pump Model MCK020 025BR Outdoor Unit Model MLC020 025BR 59...
Page 61: ...Indoor Unit Heat Pump Model MCK030BR Outdoor Unit Model MLC030BR 60...
Page 62: ...Indoor Unit Heat Pump Model MCK030BR Outdoor Unit Model MLC030CR 61...
Page 63: ...Indoor Unit Cooling Only Model MCK010 015C Outdoor Unit Model MLC010 015B 62...
Page 64: ...Indoor Unit Cooling Only Model MCK020C Outdoor Unit Model MLC020B 63...
Page 100: ...Fresh Air Kit for MCK C Models 99...
Page 101: ...2004 McQuay International 1 800 432 1342 www mcquay com ISO 9002 REGISTERED...