1-3
English
INSTALLATION DIAGRAM
Air Filter
Air Intake
Grille
Air Discharge
Louver
Air Discharge
Grille
Front Frame
Back Housing
Main Switch
ON/OFF Switch
Drain Hose
Return Air
Air Discharge Nozzle
Indicator
Light
Signal Receiver
Refrigerant Piping
Indoor Unit
Outdoor Unit
The outdoor unit must be installed such that there is no short
circuit of the hot discharge air or obstruction to the smooth
air flow. Please follow the installation clearance shown
below. Select the coolest possible place where intake air
temperature is not greater than the outside air temperature
(maximum 45°C).
Installation Clearance
Note : If there is any obstacle higher than 2m, or if there is
any obstruction at the upper part of the unit, please allow
more space than the figure indicated in the above table.
Dimension
A
B
C
D
Minimum
Distance (mm)
300
1000
300
500
Obstacle
Obstacle
Return Air
Dischar
ge Air
Obstacle
Obstacle
Return Air
Service
Access
INSTALLATION OF INDOOR UNIT
Plate Mounting
Installation
The indoor unit must be installed in such a way so as to
prevent short circuit of the cool discharged air with the hot
return air. Please follow the installation clearance shown in
the figure. Do not place the indoor unit where there could
be direct sunlight shining on it. Also, this location must be
suitable for piping and drainage, and be away from doors
or windows.
Hole With Cone Drill
Indoor Side
Outdoor Side
Screw position in the
wall
Ø 65.0 mm Hole in
the wall
Mounting Installation Plate
Ensure that the wall is strong enough to withstand the weight
of the unit. Otherwise, it is necessary to reinforce the wall
with plates, beams or pillars.
Use the level gauge for horizontal mounting, and fix it with
4 suitable screws.
In case the rear piping draws out, drill a hole 65mm in
diameter with a cone drill, slightly lower on the outside wall
(see figure).
Piping Routing
INSTALLATION OF OUTDOOR UNIT
Maintenance &
Servicing Space
Air Flow
Direction
Higher Than
Eye Level
50.0 mm
50.0 mm
50.0 mm
Routing Of Piping
Remove the screw holding the front panel.
Screw position in the wall
72.0
Centre Line
Ø 65.0 mm Hole in the wall