STANDARD OPERATING CONDITIONS

Heat Pump Unit

Cooling unit

Temperature

Ts °C

Th °C

Minimum indoor

16

11

temperature

Maximum indoor

32

23

temperature

Minimum outdoor

16

11

temperature

Maximum outdoor

43

26

temperature

Temperature

Ts °C

Th °C

Minimum indoor

16

-

temperature

Maximum indoor

30

-

temperature

Minimum outdoor

-5

-6

temperature

Maximum outdoor

24

18

temperature

Ts: Dry bulb temperature.
Th: Wet bulb temperature.

AIR CONDITIONER UNIT OPERATION

Overheating protection (for heat pump unit only)

In case the internal temperature and/or the external
temperature are to high, or that the filter is dirty and
clogged out, the refrigerant may be overheated. The
compressor will cut out when the condensing
temperature reaches 62°C.

Frost prevention

When the air filter is dirty, the evaporating temperature
will decrease and eventually cause frosting.

The LED light will blink to indicate that the filter is
dirty. If the evaporating temperature reaches -2°C, the
unit will trip and defrost.

Fan speed and rated cooling capacity

The rated cooling capacity is provided at the maximum
fan speed.

The cooling capacity is lower when the unit is operating
at MEDIUM and LOW fan speed.

Dry mode

When the air humidity is high, the unit can operate in
dry mode. Press <MODE> button and choose <DRY>.

If the room temperature is 2°C higher than the set
temperature, the air conditioner until will operate under
cooling mode until it reaches within 2°C range of
difference compared to the set temperature before it
converts to dry mode.

If the room temperature is within 2°C range of
difference compared to the set temperature, it will
directly operate under dry mode.

The unit will operate at LOW speed under dry mode.

Heat mode (for heat pump unit only)

When the unit is switched on from cold start or
defrosting cycle, the indoor fan will start to operate only
after the coil reaches the desired temperature.

When the set temperature is achieved, the indoor fan
will operate until the coil cannot provide anymore
additional heat.

!

 Warning

Disconnect from the main power supply before servicing the air conditioner unit.

DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result
in fire hazards.

AUTO RANDOM RE-START FUNCTION

If there is a power cut when the unit is operating, it will automatically resume the same operating mode when the power is
restored. (Applicable only to units with this feature)

!

 Caution

Before turning off the power supply, set the remote controller's ON/OFF switch to the “OFF” position to prevent the
nuisance tripping of the unit.

If this is not done, the unit's fans will start turning automatically when power resumes, posing a hazard to service
personnel or the user.

CED1099 (10~14/E)

2/1/01, 3:48 PM

13

Summary of Contents for ALC20B

Page 1: ...CEILING FLOOR EXPOSED CONVERTIBLE SPLIT TYPE AIR CONDITIONERS INSTALLATION MANUAL...

Page 2: ...SL50CR Model RCM20D MCM020D YCE20D LXCM20D ALC20B MLC020B YSL20B LXLC20B RCM25D MCM025D YCE25D LXCM25D ALC25B MLC025B YSL25B LXLC25B RCM30D MCM030D YCE30D LXCM30D ALC30C MLC030C YSL30C LXLC30C RCM40D...

Page 3: ...Safety Precautions page 2 Air Conditioner Parts Description page 3 Outline And Dimensions page 3 Installation Of Indoor Unit page 5 Installation Of Outdoor Unit page 7 Refrigerant Piping page 7 Elect...

Page 4: ...IT AIR DISCHARGE LOUVER OUTDOOR UNIT AIR INTAKE AIR DISCHARGE NOZZLE REFRIGERANT PIPING SIGNAL RECEIVER INDICATOR LIGHTS AIR DISCHARGE GRILLE AIR INTAKE GRILLE AIR FILTERS INSIDE AIR INTAKE GRILLE OUT...

Page 5: ...9 1379 1379 M 517 517 517 517 517 OUTDOOR UNIT SL SERIES MODEL A B C D E F G H J K L M N P Q R SL 20B 20BR SL 25B 25BR 840 646 330 297 309 626 46 90 64 177 106 408 378 124 492 78 5 SL 30B 30BR SLC SER...

Page 6: ...welding transformers which can cause high supply fluctuation Ensure that the installation location is convenient for wiring and piping STANDARD MOUNTING Ensure that the overhead supports are strong en...

Page 7: ...o a false ceiling please check that the unit is well aligned Provide the installation space as shown in figure D CEILING TYPE FIGURE C FLOOR STANDING TYPE CEILING BOARD TOP PANEL OF UNIT UTENSILS FURN...

Page 8: ...Dimension A B C D Minimum Distance mm 300 1000 300 500 REFRIGERANT PIPING MAXIMUM PIPE LENGTH AND MAXIMUM NUMBER OF BENDS If the pipe length is too long both the capacity and the reliability of the u...

Page 9: ...rough coil and joints while the brazing work is being done This will eliminate soot formation on the inside walls of the copper tubings Cut the connection pipe with a pipe cutter Remove burrs from cut...

Page 10: ...minimum contact gap of 3mm TERMINAL STRIP INDOOR UNIT INTERCONNECTION CABLE TERMINAL STRIP OUTDOOR UNIT COMP L N N COMP N Model 20D 25D 30D Voltage range 220V 240V 1Ph 50Hz Power Supply Cable size mm2...

Page 11: ...they should be checked and selected to comply with the local and or national codes and regulations They are also subjected to the type of installation and size of conductors used The electrical power...

Page 12: ...or national codes and regulations They are also subjected to the type of installation and size of conductors used N L COMP A 4WV OF N L COMP A 4WV OF S N T R TERMINAL STRIP INDOOR UNIT INTERCONNECTIO...

Page 13: ...d screw Additional charge The refrigerant is pre charged in the outdoor unit If the piping length is less than 5m then additional charge after vacuuming is not necessary If the piping length is more t...

Page 14: ...DE button and choose DRY If the room temperature is 2 C higher than the set temperature the air conditioner until will operate under cooling mode until it reaches within 2 C range of difference compar...

Page 15: ...e power plug is disconnected It is possible that your delay timer has been set incorrectly If the fault persist after all these verifications please contact the air conditioner unit installer The air...

Page 16: ...reils pr sent s dans ce manuel Im Falle einer widerspr chlichenAuslegung der vorliegendenAnleitung bzw einer ihrer bersetzungen gilt dieAusf hrung in Englisch nderungen von Design und technischen Merk...

Reviews: