MCOHome  Water  /  Electrical  Heating  Thermostat  is  a  Z-Wave  Plus  enabled  device  for 

indoor  temperature  control.  MH7H-WH  is  mainly  applied  to  control  wall  mounted  boiler,  water 

valve/pump  etc.  ,  while  MH7H-EH  is  for  electrical  heating  system.  The  device  is  of  high 

reliability  and  practicability,  which  can  be  included  and  operated  in  any  Z-Wave  network  with 

other  Z-Wave  certified  devices  from  any  other  manufacturers.  All  non-battery  operated  nodes 

within the network will act as repeaters regardless of vendor to increase reliability of the network.   

 

Features

 

 

Capacitive touch buttons   

 

Tempered glass panel, PC alloy enclosure 

 

Precise temperature calibration function 

 

Attractive appearance 

 

Clear display, easy to operate   

                                                              Specification                                                       

 

Power Supply

AC85-260V, 50/60HZ 

 

Output: MH7H-WH ≤5A ; MH7H-EH≤ 16A 

 

Self Consumption

≤1W 

 

External Temp. Sensor(optional): NTC    R25

=15K

Ω

    B25

/50

=3550K   

 

Working Environment

0-50

;    0-90% RH

Non-condensation) 

 

Temperature Setting

5-37 

(41-99℉)

Adjustable

 

 

Dimension

86* 86*15mm   

 

Hole Pitch

60-61mm   

                                                               

  Safety Information   

                                                   

To protect yourself and others from danger and to protect the device from damage, please read the 

safety information before using it. 

Important! 

 

 

A qualified electrician with the understanding of wiring diagrams and knowledge of electrical 

safety should complete installation following the instructions. 

 

Before installation, please confirm the real voltage complying with the device’s specification. 

Cut off any power supply to secure the safety of people and device.   

 

During installation, protect the device from any physical damage by dropping or bumping. If 

happens, please contact the supplier for maintenance. 

 

Keep  the  device  away  from  acid-base  and  other  corrosive  solids,  liquids,  gases,  to  avoid 

damage.   

 

Avoid overexertion during operation, to protect device from mechanical damage. 

 

Read all instructions and documentation and save for future reference. 

Summary of Contents for MH7H-WH

Page 1: ...H 5A MH7H EH 16A Self Consumption 1W External Temp Sensor optional NTC R25 15K B25 50 3550K Working Environment 0 50 0 90 RH Non condensation Temperature Setting 5 37 41 99 Adjustable Dimension 86 86...

Page 2: ...ice is well mounted power on and it is ready to operate L N COM NC NO L N Passive com Normal open Normal close L N COM L N Valve NC NO T T T T Sensor Sensor L N T T L N Elec OUT Sensor 1 Passive Wall...

Page 3: ...is 5 37 41 99 Then press S4 or S5 can adjust the value Press S3 or wait 25 seconds without any key operation will save the setting and return back to the normal operation interface Auto Mode The chan...

Page 4: ...o the normal working interface In this time vacation mode icon displays and device will follow the setting Long press S2 again will end vacation mode and resume to normal work vacation mode icon will...

Page 5: ...display the indoor temperature and high temperature protection icon When it is under high temperature protection high temperature protection icon flickers Humidity display operation In normal working...

Page 6: ...o Away heating mode Vacation Users can set these 4 modes via COMMAND_CLASS_THERMOSTAT_MODE And COMMAND_CLASS_BASIC can switch among Heating mode Energy saving heating mode COMMAND_CLASS_THERMOSTAT_SET...

Page 7: ...24 hours P05 EH negative deadband 1 5 3 0 0 10 0 0 18 WH negative deadband 0 5 1 0 0 10 0 0 18 P06 EH positive deadband 0 0 00 0 0 10 0 0 18 WH Temp positive deadband 0 5 1 0 0 10 0 0 18 P07 Anti fre...

Page 8: ...t OC OC OF OC Celsius OF Fahrenheit P18 Restore factory setting Display 53 Password 55 00 99 Change 53 to 55 and press S3 to confirm Please use this procedure only when the network primary controller...

Reviews: