background image

 

                                                      www.mcohome.com                                        User Manual

 

MCOHome Technology Co., Ltd     

     

 

3

 

                                                            Button & Display                                                 

 

 

                                                                Operation                                                           

 

On/Off operation 

When power on, thermostat displays “OFF”

all outputs are forced off. Touch S3 button to 

switch (manual/off/auto) mode, then press S2 to confirm and proceed power on/off setting. After 

power  on,  device  displays  current  week,  local  time,  working  mode,  current  temperature,  output 

status etc. 

 

Note: After the backlit goes out, please press the button to light up the backlit first, then press the 

button again for corresponding operation. 

 

Temperature setting 

In normal working status, press S4 or S5 button will enter into temperature setting interface. 

The setting range is 5-37 

(41-99℉).

 Then press S4 or S5 can adjust the value. Press S3 or wait 

25 seconds without any key operation will save the setting and return back to the normal operation 

interface.   

Auto Mode: 

The changed value only valid in the current time period for this time, and   

                      the device will not affect the preset time period value . 

Manual Mode: 

The changed value will be valid until next setting.

 

Vacation Mode: 

The changed value will be valid until next setting. 

 

Key lock function 

     

  In  normal  operating  interface,  long  press  S1+S4  button, 

  icon  appear  that  indicates  the 

button is locked, at  this time all buttons are  disabled; When  long press S1+S4 button again, 

 

icon disappear that indicates the button is unlocked, all buttons back to normal work. 

 

Control specifications   

MH7H-WH 

 

Detection  temperature  <  setting  temperature  -  0.5

,  output  turns  on,  and  output  icon 

displays.   

Summary of Contents for MH7H-WH

Page 1: ...H 5A MH7H EH 16A Self Consumption 1W External Temp Sensor optional NTC R25 15K B25 50 3550K Working Environment 0 50 0 90 RH Non condensation Temperature Setting 5 37 41 99 Adjustable Dimension 86 86...

Page 2: ...ice is well mounted power on and it is ready to operate L N COM NC NO L N Passive com Normal open Normal close L N COM L N Valve NC NO T T T T Sensor Sensor L N T T L N Elec OUT Sensor 1 Passive Wall...

Page 3: ...is 5 37 41 99 Then press S4 or S5 can adjust the value Press S3 or wait 25 seconds without any key operation will save the setting and return back to the normal operation interface Auto Mode The chan...

Page 4: ...o the normal working interface In this time vacation mode icon displays and device will follow the setting Long press S2 again will end vacation mode and resume to normal work vacation mode icon will...

Page 5: ...display the indoor temperature and high temperature protection icon When it is under high temperature protection high temperature protection icon flickers Humidity display operation In normal working...

Page 6: ...o Away heating mode Vacation Users can set these 4 modes via COMMAND_CLASS_THERMOSTAT_MODE And COMMAND_CLASS_BASIC can switch among Heating mode Energy saving heating mode COMMAND_CLASS_THERMOSTAT_SET...

Page 7: ...24 hours P05 EH negative deadband 1 5 3 0 0 10 0 0 18 WH negative deadband 0 5 1 0 0 10 0 0 18 P06 EH positive deadband 0 0 00 0 0 10 0 0 18 WH Temp positive deadband 0 5 1 0 0 10 0 0 18 P07 Anti fre...

Page 8: ...t OC OC OF OC Celsius OF Fahrenheit P18 Restore factory setting Display 53 Password 55 00 99 Change 53 to 55 and press S3 to confirm Please use this procedure only when the network primary controller...