background image

 

  www.mcohome.com                                        User Manual                                                                           

 

MCOHome Technology Co., Ltd                                2

 

   

 

   

                                                                       

Operation

                                                                         

INCLUDING the device into Z-Wave network: 

1.

 

Set controller into INCLUSION mode. Follow instructions provided by controller manufacturer. 

2.

 

Press and hold any key on the panel for 8 seconds.   

Note: If inclusion is successful, all INDICATION LEDs on the panel will turn green, and all switches 

will turn on.   

 

EXCLUDING the device from Z-Wave network: 

1.

 

Set controller into EXCLUSION mode. Follow instructions provided by controller manufacturer. 

2.

 

Press and hold any key on the panel for 8 seconds. 

Note:  If  the  exclusion  is  successful,  all  INDICATION  LEDs  on  the  panel  will  turn  orange,  and  all 

switches will turn off. The exclusion will delete all association data. 

 

Turning on/off the device:     

The device can be controlled by: 

 

Pressing any key. 

 

Sending  commands  through  controller  or  gateway.

the  command  classes  which  support  this 

function  are  Basic  Command  Class,  Binary  Command  Class,  Switch  All  Command  Class,  and 

Multi Channel Command Class.

 

 

Multi Channel Control: 

The  switch  can  be  controlled  by  command  “MULTI_CHANNEL_ENCAP”  in  the  command  class 
“COMMAND_ CLASS_MULTI_CHANNEL”. 

Byte 

Name 

COMMAND_CLASS_MULTI_CHANNEL 

MULTI_CHANNEL_CMD_ENCAP 

Source End Point 

Destination End Point 

COMMAND_CLASS_SWITCH_BASIC or COMMAND_CLASS_SWITCH_BINARY   

BASIC_SET/BASIC_GET or BINARY_SET/BINARY_GET 

Value ( 0xFF -- ON    0x0 -- OFF ) 

 

Multi Channel Association: 

To  set  association  groups  by  the  command  “COMMAND_CLASS_MULTI_CHANNEL_ 

ASSOCIATION”. 

The device supports 3 association groups (AG). The 1

st

 AG is used for reporting devices’ state to 

the controller if any changes happen. This group supports one Node, which suggested to be controller 

Node. The rest 2 AGs is used for switching associated devices

and it can support up to 5 nodes or 

terminals.   

For  the  1

st

  AG,  a  report  will  be  sent  to associated  controller  when  any  state  changes  happen  in 

other  group(s).  For  the  rest  2  AGs,  the  touch panel  switch  will  send  Basic  Set  Command  to  related 

association  groups  when  setting  switch  state  by  gateway  or  key-pressing.  Then  the  switch  states  of 

associated devices and their related key will be synchronic (S1-AG2, S2-AG3). 

Reviews: