background image

 

  www.mcohome.com                                        User Manual                                                                           

 

MCOHome Technology Co., Ltd                                3

 

   

 

 

Scene Function: 

As  a  Scene  device,  it  supports  “Scene  Activation  CC”  and  “Scene  Actuator  Conf  CC”  ,which 

make the device can be added into any scene , and supports 255 Scene ID. In parameter item4, users 

can configure which external switch will respond the scene CC . 

 

Parameters Setting: 

Add

 

Function

 

Byte

 

Options

 

Default

 

Remark

 

Switch state saved or 

not when power 

failure 

0x00 not saved

switch will be off when 

powered again 

0x01 saved

switch will keep the same 

state when powered again 

0x01 

 

RESERVED 

 

 

 

 

LED Backlit 

brightness level 

0x00 LED disabled 

0x01~0x0A Min level-Max level 

0x0A 

 

Scene respond 

0x00    All switches respond Scene CC 

0x01    only S1 respond 

0x00 

 

ALL ON/ALL OFF   

0x00 forbid ALL ON, forbid ALL OFF 

0x01 forbid ALL ON, allow ALL OFF 

0x02 allow ALL ON, forbid ALL OFF 

0xFF allow ALL ON, allow ALL OFF 

0xFF 

 

255 

Factory setting 

0x55    restore factory setting   

 

write only 

 

Restoring Factory Settings 

Pls follow the EXCLUDING operation to restore the factory setting. 

 

                                                           

  SAFETY NOTICE   

                                                               

1.  Flush-mount  only  into  a  UL/ETL/CE  certified  plastic  junction  box  and  switch  panel  cover.  The 

minimum size should be 90*60*50mm, minimum Volume is 270cm

3

.

 

 

2. Use Copper Conductors Only. 

3.  CAUTION  -  Risk  of  Electric  Shock  -  More  than  one  disconnect  switch  may  be  required  to 

de-energize the equipment before servicing. 

 

FCC Warning (Part 15.21) (USA only) 

Changes or modifications not expressly approved by the party responsible for compliance could void 
the user’s authority to operate the equipment. 

 

FCC Interference Statement (Part 15.105 (b)) (USA only) 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B  digital  device, 

pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection 

against  harmful  interference  in  a  residential  installation.  This  equipment  generates,  uses,  and  can 

radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 

cause harmful interference to radio communications. However, there is no guarantee that interference 

Reviews: