www.mcohome.com
User Manual
MCOHome Technology Co., Ltd
4
SAFETY NOTICE
1. Flush-mount only into a UL/ETL/CE certified plastic junction box and switch panel cover. The
minimum size should be 65*65*45mm, minimum Volume is 190cm
3
.
2. Use Copper Conductors Only.
3. CAUTION - Risk of Electric Shock - More than one disconnect switch may be required to
de-energize the equipment before servicing.
1-year Limited Warranty
We warrant this product to be free from defects in material and workmanship under normal and proper use for one year from
purchase date of the original purchaser. We will, at its option, either repair or replace any part of its products that prove defective
by reason of improper workmanship or materials. THIS LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO
THIS PRODUCT THAT RESULTS FROM IMPROPER INSTALLATION, ACCIDENT, ABUSE, MISUSE, NATURAL
14
Double click of S1
1
0x00
function disabled
0x01
reach max brightness level
0x01
15
Operation report
from Switch1 to
Association Group
2 & 3
1
bit 6:0
0x00
report all operation to AG2&3
0x01
only report when switching
OFF
0x02
only report when switching
ON
bit7 (valid for AG3 during dimming only)
0
not report during dimming
1
report during dimming
0x00
Device send Basic
Set to AG2;
Send Multilevel
Set to AG3.
16
Operation report
from Switch1 to
Association Group
2
1
0x00
When sent Basic Set On,
carried Value is 0xFF
0x01
When sent Basic Set On, carried
Value is Current Dimmer Value
0x01
17
EMPTY
18
EMPTY
19
Scene ID sent to
AG1 when one
click of S1
1
0
Scene Activation disabled
1~255
send Activation CC to AG1
with
specified Scene ID
0x00
20
Scene ID sent to
AG1 when double
click of S1
1
0
Scene Activation disabled
1~255
send Activation CC to AG1
with
specified Scene ID
0x00
For momentary
button only
21
Scene ID sent to
AG1 when hold
S1
1
0
Scene Activation disabled
1~255
send Activation CC to AG1
with
specified Scene ID
0x00
For momentary
button only
255
Factory setting
1
0x55
restore factory setting
write only