Parameters Setting:
Add
Function
Byte
Options
Defaul
t
Remark
1
Dimmer state
saved or not
when power
down
1
0x00
not saved
,
Dimmer will be off
when powered again
0x01
saved
,
Dimmer will keep the
same state when powered again
0x01
2
Beep
1
0x00
Beep disabled
0x01
Beep enabled
0x01
3
LED Backlit
brightness level
1
0x00
LED disabled
0x01~0x0A
Min level-Max level
0x0A
4
ALL ON/ALL OFF
1
0x00
forbid ALL ON, forbid ALL OFF
0x01
forbid ALL ON, allow ALL OFF
0x02
allow ALL ON, forbid ALL OFF
0xFF
allow ALL ON, allow ALL OFF
0xFF
5
Minimum
brightness level
1
1~98
percentage brightness level
0x01
The max level
should always
higher than min
level
6
Maximum
brightness level
1
2~99
percentage brightness level
0x63
7
Single dimming
step time(Manual)
2
Max 2.55s, in 10ms steps
0x03
(30ms)
Manual control
realized by
holding external
button
8
Single dimming
step size(Manual)
1
1~99
percentage value
(modification isn’t recommended)
0x01
9
Single dimming
step time (Auto)
2
Max 2.55s, in 10ms steps
0x03
(30ms)
Auto control
realized by:
- one click;
- double click of
external button;
- send
Z-Wave
CC
10
Single dimming
step size (Auto)
1
1~99
percentage value
(modification isn’t recommended)
0x01
11
Timer function
(Auto-off)
2
0x00
function disabled
0x0001~0x00FF
1s~255s
0x00
12
Reserved
13
One click of S1
1
0x00
switch between Off and last saved
brightness level
1~99
percentage value
switch between Off and the set value
99