Please note: Warranty effective at time of shipment. Pentair Technical Products warrants that all material and 

workmanship are free of defects in quality which impair the usefulness of the thermoelectric cooler or heat 

exchanger for a period of five (5) years for nonoperating parts, except for the filter; and for one (1) year for 

everything else when installed and operated under the following conditions:

A.  Maximum voltage variation no greater than plus or minus 10% of nameplate nominal rating.
B.  Maximum frequency variation no greater than plus or minus 3 Hz. of nameplate nominal rating.
C.  Must not exceed minimum and maximum stated temperatures on the nameplate.
D.  Not to exceed (BTU/Hr.) rating, including any heat sink, as indicated on the nameplate.
E.  The unit must not be restarted for a period of one (1) minute after intentional or accidental shut-off. (This 

does not apply to heat exchanger or filter fan.)
Pentair Technical Products warrants that all material and workmanship are free of defects in quality which 

impair the usefulness of the filter fan package and all custom thermoelectric coolers and heat exchangers for a 

period of one (1) year, except for the filter, when installed and operated under conditions A, B, C and D as listed 

above.
Not covered in this warranty is damage to the thermoelectric cooler or heat exchanger due to the introduction 

of other than the nameplate-designated refrigerant. Operation of any Pentair Technical Products product that 

has not been designed with proper protective coatings and/or options and is in an abnormal or corrosive 

environment voids the warranty. Prolonged operation with dirty filters also voids the warranty.
Should any part prove defective within the above warranty period, the customer may choose to return the 

defective product that is under warranty to Pentair Technical Products for repair at no charge or the customer 

has the option to repair the defective products at his own expense and Pentair Technical Products will supply 

repair parts at no charge providing the defective part is returned and found to have failed under warranty. 

Parts supplied as warranty replacement parts will assume the balance of the warranty on the part returned for 

warranty consideration.
Please be advised: According to the Federal Register, no person maintaining, servicing, repairing, or disposing 

of appliances may knowingly vent or otherwise release into the environment any class I or class II substance 

used as refrigerant.
Pentair Technical Products assumes no liability beyond the repair or replacement of its own product. Customer 

modification of any Pentair Technical Products product voids this warranty.
The purchaser assumes the responsibility of grounding the unit and installing it in accordance with local 

electrical and safety codes, as well as the National Electric Code (NEC) and OSHA.
This express warranty constitutes the entire warranty with respect to the PRODUCT and IS IN LIEU OF ALL 

OTHERS, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OR MERCHANTABILITY AND WARRANTY OF 

FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT IS PENTAIR TECHNICAL PRODUCTS RESPONSIBLE FOR 

ANY CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER.

Summary of Contents for HB16 Series

Page 1: ...v I P N 10 1008 06 Protecting Electronics Exceeding Expectations Pentair Equipment Protection 2100 Hoffman Way Minneapolis MN 55303 USA 1 763 422 2211 1 763 576 3200 PentairEquipmentProtection com INS...

Page 2: ...bility for freight damages however we are ready to assist you in any way possible NOTE Some of the information in this manual may not apply if a special unit was ordered If additional drawings for a s...

Page 3: ...Do not attempt to operate the air conditioner while it is horizontal or on its side back or front The refrigeration compressor is filled with lubricating oil This will cause permanent damage to the a...

Page 4: ...oltage Hertz Full Load Amps Phase BTU Hr Maximum Ambient Temperature Maximum F Ambient Temperature Shipping Weight lb kg HB160816GXXX 115 50 60 18 8 20 4 1 7075 8133 131 145 66 HB160826GXXX 230 50 60...

Page 5: ...l air blower located in the bottom of the unit and the compressor should be running To check cool air output use a reliable air temperature measuring device The cool air should be between 50 F 10 C an...

Page 6: ...ust be of sufficient size to handle the air flow 25 in 2 minimum Keep in mind that reduction of air flow will impair air conditioner performance Also remember that this air is hot and relatively dirty...

Page 7: ...A 5 inch 13 mm inside diameter drain tube exists on the side of the air conditioner and must be routed over the side A pressure relief fitting has been provided to assist in venting any air blockage t...

Page 8: ...y frequent cleaning and or replacement the inlet filter will assure relatively clean air to pass through the condenser coil Dirty filters will hamper the optimum operating efficiency of the air condit...

Page 9: ...mended that power to the air conditioner be interrupted intentionally when abnormally high compressor operating temperatures cause automatic shut down of the unit The above described shut down is symp...

Page 10: ...r disposable filters and filter adhesive see parts list in Table 1 on page 12 1 Flush the filter with warm water from the exhaust side to the intake side DO NOT use caustics 2 After flushing allow fil...

Page 11: ...hnical Products 87976428 11 Dimensional Drawings 5 5 7851 1 2685 22 5 287 5 287 0 17 0 17 5 1 6 59 25 URQW 9LHZ 6LGH 9LHZ 5HDU 9LHZ 1 5 86 80 180 1 7 7 5 81 5 1 26 RWWRP 9LHZ XWRXW HB16 Models 8000 BT...

Page 12: ...Only 35 See Table 1 1 Switch Compressor Thermal Overload 38 See Table 1 1 Compressor 39 See Table 1 1 Power Cord 47 52 6028 00 1 Filter Dryer Refrigerant 48 52 6027 00 1 Valve Hot Gas By Pass 230V Onl...

Page 13: ...2013 Pentair Technical Products 87976428 13 Parts Exploded View...

Page 14: ...2013 Pentair Technical Products 87976428 14 Wiring Schematic...

Page 15: ...2013 Pentair Technical Products 87976428 15 Electrical Schematic...

Page 16: ...2013 Pentair Technical Products 87976428 16 Notes...

Page 17: ...2013 Pentair Technical Products 87976428 17 Notes...

Page 18: ...has not been designed with proper protective coatings and or options and is in an abnormal or corrosive environment voids the warranty Prolonged operation with dirty filters also voids the warranty S...

Page 19: ...ntair Technical Products in writing of any such claim or demand provided further that Pentair Technical Products shall have the right and option to undertake and control the entire defense of such cla...

Page 20: ...cal Products 87976428 Rev I P N 10 1008 06 Protecting Electronics Exceeding Expectations Pentair Equipment Protection 2100 Hoffman Way Minneapolis MN 55303 USA 1 763 422 2211 1 763 576 3200 PentairEqu...

Reviews: