background image

Page 11 

 

10-1008-05 Rev 1 

MCLEAN COOLING TECHNOLOGY WARRANTY 

 

Please note: Warranty effective at time of shipment. 
McLean Cooling Technology warrants that all material and workmanship are free of defects in quality which 
impair the usefulness of the air conditioner or heat exchanger for a period of five (5) years for non-operating 
parts, except for the filter; and for one (1) year for everything else when installed and operated under the 
following conditions: 
 

A. Maximum voltage variation no greater than plus or minus 10% of nameplate nominal rating. 

 

B. Maximum frequency variation no greater than plus or minus 3 Hz. of nameplate nominal rating. 

 

C. Must not exceed minimum and maximum stated temperatures on the nameplate. 

 

D. Not to exceed (BTU/Hr.) rating, including any heat sink, as indicated on the nameplate. 
E. The unit must not be restarted for a period of one (1) minute after intentional or accidental shut-off. 
(This does not apply to heat exchanger or filter fan.) 
F. Extended operation with thermostat stop screw removed and setting below 70°F. 
 

McLean Cooling warrants that all material and workmanship are free of defects in quality which impair the 
usefulness of the filter fan package and all custom air conditioners and heat exchangers for a period of one (1) 
year, except for the filter, when installed and operated under conditions A, B, C and D as listed above. 
 
Not covered in this warranty is damage to the air conditioner or heat exchanger due to the introduction of other 
than the nameplate-designated refrigerant. Operation of any McLean Cooling product that has not been 
designed with proper protective coatings and/or options and is in an abnormal or corrosive environment voids 
the warranty. Prolonged operation with dirty filters also voids the warranty. 
 
Should any part prove defective within the above warranty period, the customer may choose to return the 
defective product that is under warranty to McLean Cooling for repair at no charge or the customer has the 
option to repair the defective products at his own expense and McLean Cooling will supply repair parts at no 
charge providing the defective part is returned and found to have failed under warranty. Parts supplied as 
warranty replacement parts will assume the balance of the warranty on the part returned for warranty 
consideration. 
 
Please be advised: According to the Federal Register, no person maintaining, servicing, repairing, or disposing 
of appliances may knowingly vent or otherwise release into the environment any class I or class II substance 
used as refrigerant. 
 
McLean Cooling assumes no liability beyond the repair or replacement of its own product. Customer 
modification of any McLean Cooling product voids this warranty. 
 
The purchaser assumes the responsibility of grounding the unit and installing it in accordance with local 
electrical and safety codes, as well as the National Electric Code (NEC) and OSHA. 
 
This express warranty constitutes the entire warranty with respect to the PRODUCT and IS IN LIEU OF ALL 
OTHERS, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OR MERCHANTABILITY AND 
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT IS MCLEAN 
COOLINGRESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER. 
 
HOLD HARMLESS 
In consideration of purchase of equipment from McLean Cooling by a customer, McLean Cooling agrees to 
indemnify and hold harmless such customer and users with a defense, as to any claim, demand, statutory court 
cost, fees for attorney's services provided for below, and/or judgment, for actual of alleged patent infringement in 
any country, arising out of the use, sale or advertisement of any equipment manufactured or sold by McLean 
Cooling to McLean Cooling’s own specifications, provided that the customer or user shall promptly notify 
McLean Cooling in writing of any such claim or demand, provided further that McLean Cooling shall have the 
right and option to undertake and control the entire defense of such claim, or demand instituted against the 
customer or user, but limited to the products made or sold by McLean Cooling, through counsel selected by 
McLean Cooling, and to settle and pay any claim award arising out of such claim or demand, and provided 
further that the customer or user will provide such information and assistance as McLean Cooling may request 
subject to reimbursement by McLean Cooling for any out-of pocket expense incurred in providing such 
requested assistance. Liability of McLean Cooling for any infringement or claim thereof shall be limited to the 
above undertaking.

 

Summary of Contents for LOBOY 16

Page 1: ...STRUCTION MANUAL FOR LOBOY 16 AIR CONDITIONERS McLean Midwest Corp dba McLean Cooling Technology 11611 Business Park Blvd N Champlin MN 55316 Tel 763 323 8200 Fax 763 576 3200 www mcleancoolingtech co...

Page 2: ...in it is placed in an upright vertical or mounting position for a minimum of five 5 minutes before operating Warning Do not attempt to operate the air conditioner while it is horizontal or on its side...

Page 3: ...air conditioner and the approximate height i e LB16 LOBOY family about 16 high 2 This is the air conditioner s listed capacity in Btu hr at rated conditions i e 10 10 000 Btuh at 125 125F 3 1 115 Volt...

Page 4: ...ith the mounting gasket attached as this could cause rips or tears in the gasket and risk losing the water tight seal Step 4 Allow unit to remain upright for a minimum of five 5 minutes before startin...

Page 5: ...tain is limited If moisture flows from the drain tube continuously this can only mean that ambient air is entering the enclosure Be aware that frequent opening of the enclosure s door admits humid air...

Page 6: ...5 26 1 17 3 9 3 85 29 4 179 2 153 1 10 23 3 21 1 12 4 90 32 2 193 6 166 5 5 20 6 25 2 15 8 95 35 208 8 180 8 0 17 8 29 6 19 5 100 37 8 224 9 195 8 5 15 34 4 23 6 105 40 6 241 8 211 8 10 12 2 39 6 28 1...

Page 7: ...p 125 F 52 C Minimum Ambient Temp 40 F 40 C Condensate Management Hose discharge Electrical Data Rated Voltage 50 60 Hz 230 V Rated Frequency 50 60 Hz Voltage Range 10 of rated Cooling Amps at Max Con...

Page 8: ...Page 7 10 1008 05 Rev 1 Wiring Point to Point Diagram Figure 3 Wiring Diagram...

Page 9: ...frigerant Loss Each air conditioner is thoroughly tested prior to leaving the factory to insure against refrigeration leaks Shipping damage or microscopic leaks not found with sensitive electronic ref...

Page 10: ...thermostat Open motor winding Stuck blower motor Obstructed wheels blades 6 Carefully check the compressor for operation motor should cause slight vibration and the outer case of the compressor shoul...

Page 11: ...r tries to start but won t run Low line voltage at start Should be 10 rated voltage Compressor motor stuck Bad contactor Bad overload switch Bad run start capacitor Unit blows breakers Under sized bre...

Page 12: ...rranty Parts supplied as warranty replacement parts will assume the balance of the warranty on the part returned for warranty consideration Please be advised According to the Federal Register no perso...