background image

17

Your McIntosh MA352 has been factory configured to 

allow immediate enjoyment of superb audio without 

the need for further adjustments. If you wish to make 

changes to the factory default settings, a Setup Fea-

ture is provided to customize the operating settings 

using the Front Panel Information Display. Refer to the 

MA352 Front Panel Illustration on the previous page 

while performing the following steps.

Note: If the MA352 is currently On, proceed to step 2.

1. Press the Volume Control on the MA352 or press 

the      (Power ON) Push-button on the Remote 

Control to switch On the MA352. Refer to page 9 

for information about Switching Power On to the 

MA352. After the MA352 goes through its start-

up, the Front Panel Information Display indicates 

the last used source and volume setting. This is 

followed by the volume setting indication starting 

at zero and then increasing to the last used volume 

setting. Refer to figure 1.

2. Press and hold in the INPUT Control until 

the Front Panel Information Display indicates 

“MA352   V1.00, (or higher Firmware version)

     - S/N:  AHN____” (Serial Number). Refer to 

figure 2.

3. Rotate the INPUT Control to select the Setup 

Mode Menu item, “SETUP: Inputs, (Hold IN-

PUT)”. Refer to figure 3. 

Continue to rotate the INPUT CONTROL to view 

the other SETUP Mode Options.

4. To exit from the SETUP Mode, press and hold in 

the INPUT Control and the Front Panel Display 

will indicate its normal display. Refer to figure 1.

How to Operate the Setup Mode

The Default Settings Chart below indicates the Func-

tion Name, Default Setting and the Page Number for 

additional information.

Default Settings

Setup

Figure 2

   MA352     V1.00

   S/N:  AHN____

Figure 1

UNBAL 1       15%

The MA352 provides the ability to switch unused 

INPUTS Off (or back On if they have been previously 

switched Off). The default INPUT Names can be 

changed to match the name of the component con-

nected to it or any other custom name desired (within 

10 Characters).

INPUT SWITCHED ON/OFF:

In the following example, the UNBAL 3 Input will be 

switched Off.

Note: When an INPUT is swiched Off, its name will 

no longer appear on the Front Panel Informa-

tion Display when using the INPUT Control 

(Front Panel or Remote Control).

1. Press and hold in the INPUT Control to enter the 

SETUP MODE. Refer to figure 3.

2. Rotate the INPUT Control until “SETUP: Inputs, 

(Hold INPUT)” appears on the Information Dis-

play. Refer to figure 3.

3. Press and hold in the INPUT Control until “SET-

UP:  UNBAL 3, On / Name (Hold IN)” appears on 

the Display. If necessary rotate the INPUT Control 

to select the UNBAL 3 Input. Refer to figure 4.

4. To switch the UNBAL 3 Input Off, rotate the 

VOLUME Control until the display indicates 

“SETUP:  UNBAL 3,  Off”. Refer to figure 5.

Input Settings

Figure 3

   SETUP: Inputs

    (Hold INPUT)

Default Settings

Function Name

Setting

Page No.

MA352

V1.00

13

INPUTS

On/Off / Rename

13-15

OUTPUT 2

Stereo / Mono

15

PASSTHRU

Various Inputs

16

DATA PORTS

(1 and 2)

All Data and 

Various Inputs

16

RS232

Comm Port Baud Rate

17

IR Codes

Normal

Front IR Sensor

Enabled

19

Auto- Off

Enabled

19

Factory Reset

Default Settings

20

The MA352 functionality is controlled by internal 

software that is know as Firmware. The Version of the 

Firmware in the MA352 can be identified at any time 

by utilizing the Setup Mode.

1. Press and hold in the INPUT Control to enter 

Setup Mode.

2. Referring to the Front Panel Information Display-

the number after the character “V” is the Firm-

ware number. Refer to figure 2.

Firmware Version

3. To exit the Setup Mode, press the INPUT Control.

Figure 4

  SETUP: UNBAL 3

 On/Name(Hold IN)

Figure 5

 SETUP: UNBAL 3

      Off

Summary of Contents for MA352

Page 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com MA352 Integrated Amplifier Owner s Manual...

Page 2: ...er name are important to you for possible insurance claim or future service The spaces below have been provided for you to record that information Serial Number ________________________________ Purcha...

Page 3: ...3 IMPORTANT INSTRUCTIONS FOR REMOVAL OF FOAM INSERT OVER THE VACUUM TUBES PRIOR TO CONNECTING THE A C POWER SUPPLY CORD START ON THE NEXT PAGE...

Page 4: ...ceable parts including the tubes If repairs are needed they must be performed by an authorized McIntosh Service Agency Follow the steps below to pre pare the MA352 for operation 1 Orient the MA352 so...

Page 5: ...mall Vacuum Tubes before the MA352 Integrated Am plifier is connected to AC Power and activated for use Failure to do so has the potential to cause physical harm to human be ings and animals This coul...

Page 6: ...n including how to disable it refer to page 21 4 When Power Amplifier Protection Circuitry of the MA352 has activated the Vacuum Tubes LEDs are illuminated continuously with the color orange and the s...

Page 7: ...Controlled Electromag netic Switches on all low level inputs and outputs The operating functions are for reliable noiseless distor tion free switching Moving Magnet Phono Inputs The MA352 Moving Magne...

Page 8: ...5 500 2K 10K BAL 1 15 9 7 8 25 1m Front View of the MA352 Top View of the MA352 Right Side View of the MA352 17 1 2 44 5cm 8 7 8 22 5cm 3 7 62cm 5 3 4 14 6cm 12 7 16 31 6cm 1 1 2 3 8cm 13 1 4 33 7CM R...

Page 9: ...ible operating life for any electronic instrument Do not install the MA352 directly above a heat generating device such as a Power Amplifier Allow at least 6 inches 15 3cm above the top 5 8 inch 1 6cm...

Page 10: ...speaker UNBALANCED INPUTS 1 2 and 3 accept high level program source signals RS232 connector for connection to a compatible control system IR INput for signals from a compatible IR Room Sensor DATA PO...

Page 11: ...tput Balanced Connectors 11 Connect the Audio Cables from the AM FM Tuner UNBAL Connectors to the MA352 UNBAL ANCED 1 Connectors 12 Connect the Audio Cables from the SACD CD Player UNBAL Connectors to...

Page 12: ...s or less 4 Ohms 14AWG 12AWG 10AWG 8 Ohms 16AWG 14AWG 12AWG 1 Prepare the Loudspeaker Hookup Cable for attach ment to the MA352 Power Amplifier Bare wire cable ends Carefully remove sufficient insulat...

Page 13: ...UBE WARMUP Refer to figure B When the tube warm up procedure has completed The illumination of the Tubes will now glow a green color this is followed by the last Input Source listened to and the volum...

Page 14: ...ith McIntosh Models displaying instructions on a video screen Press to change broadcast BANDs on a connected Tuner Select certain functions on a variety of McIntosh Models Select the DEVICE to issue a...

Page 15: ...onal information on using the HR085 Remote Control with the McIntosh Model please refer to the How to Operate starting on page 22 3 For additional information on assigning the Data Ports refer to How...

Page 16: ...c HEADPHONES for private listening INPUT Control used to select a source for listening and recording The control is also used to enter the TRIM or SETUP Modes and select the various functions Front Pa...

Page 17: ...vides the ability to switch unused INPUTS Off or back On if they have been previously switched Off The default INPUT Names can be changed to match the name of the component con nected to it or any oth...

Page 18: ...amed to match up with the compo nent connected refer to page 11 step 9 The MA352 Default Input Names UNBAL 1 BAL 1 COAX 1 etc as indicated on the Front Panel Dis play can be customized to a different...

Page 19: ...a Refer to figure 24 Setup con t Data Port The OUTPUT 2 Rear Panel Unbalanced Connectors are adjustable for their mode of operation 1 Press and hold in the INPUT Control to enter the SETUP MODE Refer...

Page 20: ...he VOLUME ADJUST Control to select Disabled Refer to figure 32 4 Exit the SETUP Mode by several presses of the INPUT Control Figure 31 SETUP Front IR Enabled Figure 32 SETUP Front IR Disabled Remote C...

Page 21: ...ADJUST Control to select Disabled Refer to figure 34 4 Press the INPUT Control to exit the Setup Mode Figure 33 SETUP Auto Off Enabled Figure 34 SETUP Auto Off Disabled Factory Reset If it becomes des...

Page 22: ...appears on the Front Panel Display Refer to figure 54 or push the INPUT Push button on the Remote Con trol to select the Phono Input Refer to figures 51 and 52 Volume Control Rotate the Front Panel VO...

Page 23: ...ately 4 seconds the Information Display returns to indicate the Source Selection and Volume Level To verify the Balance setting without changing it use the TRIM Push button and select Balance EQUALIZE...

Page 24: ...formation Display returns to indicate the Source Selection and Volume Level Figure 65 INPUT TRIM 0 0 dB Figure 67 INPUT TRIM 2 5 dB Figure 66 INPUT TRIM 4 0 dB METER ILLUMINATION The Meter Illuminatio...

Page 25: ...an be adjusted from bright to dim by performing the same type of operational steps for adjusting the METER ILLUMINATION 1 Select DISPLAY BRIGHTNESS as indicated on the Front Panel Information Display...

Page 26: ...han 2 THD with up to 16dB overdrive at 1 000Hz Frequency Response 0 0 5dB from 20Hz to 20 000Hz 0 3dB from 10Hz to 100 000Hz Preamplifier Output Impedance 500 ohms Sensitivity for rated output High Le...

Page 27: ...the proper equipment location on the bottom foam pad Failure to do this will result in shipping damage To protect the tubes during shippment the Foam Insert removed from the MA352 needs to be re inse...

Page 28: ...cts is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcin...

Reviews: