MCH M1000i User Manual Download Page 8

3

.

1

) Control Panel

1

2

3

4

5

6

7

8

9

<<08>>

3

.

2

)

 

ECON. SW (Economy control switch):

ON

OFF

ON

OFF

DC  12V

AC  Receptacle

AC

 

Pilot 

 

Indicator

 

Light

(

green

)

Overload

 

Indicator

 

Light

(

red

)

Oil  warning

 

Indicator

 

Light

(

red

)

Parallel

 

Outlets

Economy

 

Switch

Ground

 

Terminal

USB  Outlet

ECON.  SW

1

2

3

4

5

6

7

8

9


position, the economy control unit automatically 
determines the generator's proper engine speed 
based on the connected electronic load. This results
 in superior fuel economy and reduces noise. 
• When the ECON switch is turned to the "OFF" position,
 the engine runs at the rated speed of 4,850 r/min. 
Note: The ECON switch must be turned to the "OFF" 
position when using electronic devices that require 
a large starting current, such as a compressor. 

When the Engine ECON switch is turned to the "ON" 

Summary of Contents for M1000i

Page 1: ......

Page 2: ......

Page 3: ...entification 1 Control Panel 3 RESET 04 Pre operation check 1 Check oil level 2 Check fuel level 3 Check air cleaner 05 Starting the engine 06 Generator use 4 Oil Warning system 07 Stopping the engine...

Page 4: ...please carefully read the following information 04 WARNING The running generator must keep one meter distance with constructions and other electrical appliances at least Place the generator on the lev...

Page 5: ...05 SAFETY LABEL...

Page 6: ...06 2 SAFETY LABLE LOCATIONS...

Page 7: ...07 3 C IDENTIFICATION OMPONENTS CHOKE LEVER FUEL CAP VENT LEVER FUEL CAP LEFT SIDE MAINTENANCE COVER STARTER GRIP ENGINE SWITCH CONTROL PANEL SPARK PLUG MAINTENANCE COVER MUFFLER...

Page 8: ...position the economy control unit automatically determines the generator s proper engine speed based on the connected electronic load This results in superior fuel economy and reduces noise When the...

Page 9: ...voltage change turn the economy control switch to the OFF position In DC operation turn the economy control switch to the OFF position Connect both AC load and DC load turn the economy control switch...

Page 10: ...Oil Level NOTE Using non detergent or 2 stroke oil could shorten the engine s working life Using the high quality engine oil with strong detergents Using 4 stroke engine oil certified to meet or excee...

Page 11: ...unleaded gasoline Research Octane Number of 91 or higher Pump Octane Number of 86 or higher Never use stale or contaminated gasoline or an oil gasoline mixture Avoid getting dirt or water into the fu...

Page 12: ...ithout air Cleaner element otherwise that makes engine abrasion 4 3 Check Air Cleaner Check the air cleaner element to be sure it is clean and in good condition a Loosen the air cleaner maintenance co...

Page 13: ...seconds and then require additional pull 10 20 times in order to the enough fuel enter into carburetor 5 1 Turn the fuel cap vent lever to the ON position OFF O N ON FUEL CAP VENT LEVER NOTE When tra...

Page 14: ...can not restart check the oil level firstly Carburetor Modification for High Altitude Operation At high altitude the standard carburetor air fuel mixture will be too rich Performance will decrease and...

Page 15: ...s been modified for high altitude operation the air fuel mixture will be too lean for low altitude use Operation at low altitude may cause the engine to overheat and result in serious engine damage Th...

Page 16: ...ECON SW to the OFF position 6 1 1 Connect the DC receptacle to battery terminals with the charging cable WARNING For continuous operation do not exceed the rated out put power of generator Do not make...

Page 17: ...h warm water for 15min at least and call a doctor immediately If you swallow a little of battery electrolyte accidentally flush thoroughly with water your mouth and then drink large quantities of wate...

Page 18: ...e connecting them to the generator If an electrical appliance becomes abnormal sluggish or stops suddenly shut off the generator engine immediately and disconnect the appliance 6 3 AC Pilot and Overlo...

Page 19: ...If the oil warning system shuts down the engine the oil warning indicator light red will be on check the engine oil level OIL WARNING INDICATOR LIGHT RED If the overload indicator light red is on disc...

Page 20: ...p vent lever and engine switch locate the OFF position when stopping transporting and storing the generator 7 STOPPING THE ENGINE To stop the engine in an emergency turn the engine switch to the OFF p...

Page 21: ...and remove the cover 8 1 2 Remove the oil filler cap 8 MAINTENANCE The purpose of the maintenance and adjustment schedule is to keep the generator in the beset operating condition WARNING Stop the en...

Page 22: ...conforming to the environment requirement the used oil will be put into a sealed container and then be transported to the service station for recycler Do not throw it into the trash or pour it on the...

Page 23: ...ts for cleaning They are flammable and explosive under certain conditions NOTE Never run the generator without air cleaner otherwise that result in engine abrasion rapidly 8 2 1 Loosen the air cleaner...

Page 24: ...spark plug 8 3 1 Remove the spark plug maintenance cover SPARK PLUG MAINTENANCE COVER 8 3 2 Take off the spark plug cap 8 3 3 Clean the carbon deposition at the bottom of the spark plug HANDLE BAR SPA...

Page 25: ...er A used Spark plug should be tightened 1 8 to 1 4 turn with spanner 8 3 8 Reinstall the spark plug cap 8 3 9 Reinstall the spark plug maintenance cover NOTE The spark plug must be securely tightened...

Page 26: ...spark arrester from the muffle after the engine cool down 8 4 3 Remove carbon deposits of the spark arrester using a brush If the spark arrester is wear replace it 26 8 4 4 Reinstall the spark arreste...

Page 27: ...ventilated condition Avoid exposing directly in the sunshine when the generator place in the enclosed transport vehicle for a long time The high temperature inside the vehicle could cause fuel to vapo...

Page 28: ...tablespoon of clean engine oil 10 20ml into the cylinder Revolve the engine several times to distribute the oil and reinstall the spark plug 9 5 Pull the starter grip slowly until feel resistance At t...

Page 29: ...ENGINE GENERATOR 3 0L 4 5h rated power 550g kW h 5 40 1000m 61 67 dB 505 310 430mm 15kg Fuel Tank Volume Continuous Running Time FuelConsumption Max Altitude Noise dB 7m Dimensions L W H Net Weight Wo...

Page 30: ...12 WIRING DIAGRAMS 30...

Page 31: ...0 62 0 60 0 58 0 56 0 54 0 52 0 50 0 48 0 46 0 500 1000 2000 3000 4000 Ambient temperature Factor of environment correction NOTE 0 01 Relative humidity 80 correction factorC 0 02 Relative humidity 90...

Page 32: ......