Fuel tank& filter
After every 300 hrs(2)
Every year(2)
Fuel line
Every 2 years ( Replace if necessary)(2)
Clean
Check
NOTE
(1) Service more frequently when used in dusty
areas
.
(2) These items should be serviced by your
servicing dealer, unless you have the proper
tools and are mechanically proficient. Refer to
HEYA manual for service procedures.
(3) For commercial use, long hours of operation to
determine proper maintenance intervals.
8.1) Change Oil
Drain the oil rapidly and completely while the
engine is still warm.
8.1.1) Loosen the air cleaner maintenance cover
screw, and remove the cover.
8.1.
2
)
Remove the oil filler cap
.
8. MAINTENANCE
The purpose of the maintenance and
adjustment schedule is to keep the generator in
the beset operating condition.
WARNING
Stop the engine before performing any
maintenance. If the engine must run, be sure the
area is well ventilated. The exhaust contains
poisonous carbon monoxide gas.
Use genuine
or equivalen t qualit y
components to replace the wear components.
Maintenance Schedule
Each
use
Regular Service
Period (3)
Item
First
month
or
10 hrs.
Engine
oil
Check level
⊙
⊙
Change
Air
cleaner
Check
⊙
Clean
⊙
Every 3
months
or
50 hrs.
Every 6
months
or
100 hrs.
Every
2 years
or
300 hrs.
⊙
⊙
Spark arrester
⊙
Spark plug
Check-adjust
Spark plug
Valve Clearance
⊙
+(
2
)
Combustion Chamber
Clean
⊙
+(
1
)
Check-adjust
Replace