Installa� on Instruc� ons
Step 1: Determine the best loca� on for the blender! Please consider the following:
A) Select a loca� on that minimizes the chance of accidental damage to the blender.
B) Select a loca� on as near as is prac� cal to both the supply sources and the supplied equipment.
C) Select a loca� on allowing convenient access to the shut off valve for servicing.
D) Mount panel in a weather-proof area only.
Step 2: Mount panel to wall!
Step 3: Hook up gas supply and outlet!
A) Use
only
the gases shown on the panel label(s).
B) Make sure you are supplying the panel with clean, dry gases that are between the minimum and
maximum pressures as indicated on the panel label.
C) Turn shut-off valve(s) on panel to the off posi� on.
D) Make sure the tubing from the gas sources is compa� ble with the fi � ngs on the panel.
DO NOT ATTEMPT TO REMOVE INLET OR OUTLET FITTINGS.
E) Install appropriate tubing adaptors in the inlet fi � ngs. Be sure to use thread sealant and back-up
wrenches. Connect gases supply lines to inlet fi � ngs.
F) Confi rm that your system and related equipment is safe and ready for pressurized mixed gas.
G) Connect mixed gas supply tube to mixed gas outlet fi � ng.
H) Turn on the supply gases and check supply system and fi � ngs for leaks.
I) Open mixed gas supply shut off valve and check system for leaks.
Opera� on Guidelines and Helpful Hints
NOTES:
1) Supply the panel with clean gases.
2) Be sure no liquid can get into the blender as this will render it useless and void the warranty.
3) Some fi � ngs on the panel do not have standard US threads, and should not be removed with out
checking with
McDantim, Inc.
!
4)
NEVER EXCEED THE RECOMMENDED PRESSURES FOR ANY PART OF YOUR SYSTEM!
Trouble-shoo� ng: No Outlet Gas
1) Close shut-off valve. Check pressure on pressure gauge. If pressure is low or zero, check:
a) Both supply gases. (One or both could be empty, turned off or out of adjustment.)
b) For blockage of either supply line or for a closed valve within the supply system. (The blender shuts
off if either supply gas is unavailable.)
If pressure is good:
d) Open shut-off valve completely.
2) If you con� nue to have no gas, close shut-off valve, remove tubing from outlet, open shut-off valve and
check for gas fl ow.
3) If you s� ll have no supply gas, call
McDantim, Inc.
or your gas supplier or service person.
There are
no user-serviceable parts within the panel. Anything done to the internal parts will aff ect the blend
and void the warranty.
If you encounter other ques� ons or problems call:
McDantim, Inc.
(888) 735-5607 or (406) 442-5153
Warning!
With this or any compressed gas system,
there are certain dangers. If you do not have the
experience to understand these dangers, use a
professional installer.
Trumix
®
Gas Blender Panel
Installation Instructions
Use primary regulators on your
gas source suitable for your
panel specifications.
Example: If your inlet pressure
label states “Min. inlet pressure
55 psi” then you must provide at
least 55 psi to the Blender Panel.
1. Use thread sealant.
2. Do not remove fittings.
3. Use back-up wrenches.
Plug & Play In Line Leak Indicator Installation Instructions (ILLI)
(may not be included - can be purchased using part # MV098)
1. Remove vinyl caps from stand pipes and slide into female compression fittings that are installed on the McDantim Trumix® panel.
2. Tighten the compression fittings finger tight to hold the ILLI in place and screw mounting bracket securely to the wall.
3. Re-check that fittings are finger tight and then turn both compression fitting hex nuts another three quarters of a turn (14 mm size).
4. Once the ILLI is installed, hook up the inlet gases to the installed hose barbs and bring the panel up to pressure
with the outlet ball valves closed.
Note: At this point you should not see any leaks by referencing the indicator,
if you do see a leak you may need to tighten the compression fittings further.
N
2
CO
2
Use reinforced tubing suitable for 150 psi.
Mixed Gas Out
Plug & Play
ILLI
NOTE
These instructions apply to the
Trumix
®
Single
and
Trumix
®
Double
as well as their
High Flow
models.
The picture to the right is of a
Trumix
®
Double
. The
Trumix
®
Single
will have only one outlet assembly,
which is on the right-hand side.
TM-2-HPR+ILLI