USB hub 3.0 8-Port
Manual
Seite 22 von 22
Command
Parameter
Return Value
Comments
with
prefix „D“
Behavior during Standby
E
00 – FF
ok
Defines exceptions where ports are not switched off in
standby. Were the ports however off before standby, then
they will stay off. Evaluation of the parameter is on the
command ' P' as described above.
X
F
00 – FF
ok
Defines exceptions where relay multiplexers are not
turned off and in standby mode. The function is the same
as the ports.
X
R
E
00 – FF
Reading of the exceptions for the USB ports.
X
R
F
00 – FF
Reading of the exceptions for the relay multiplexer.
X
Special
ST
S | R
ok
Lock (S) or release (R) pushbutton.
X
SI
S | R
ok
Port setting according to standby mode:
S = as before standby mode
R = as after switching on
X
SC
A | E | H
ok
Choosing the control input:
A = automatic
(external when connected, hub-In
otherwise)
E = always via external connection
H = always via hub input
X
N
00 - FF
ok
Reading of the identification number (ID) to identify.
X
R
ST
S | R
Reading of the pushbutton lock.
X
R
SI
S | R
Reading of the port setting according to standby mode.
X
R
SC
A | E | H
Reading the chosen control input configuration.
X
R
N
00 – FF
Reading of the identification number (ID) to identify.
X
R
T
00 – FF
Reading the internal device temperature.
Value is 2s complement in °C.
R
V
String
Version of the firmware.
Table: Parameters for Current Limit
Parameter
Value Current Limit
Typical
Maximum
0
500mA
480mA
500mA
1
900mA
850mA
900mA
2
1000mA
950mA
1000mA
3
1200mA
1130mA
1200mA
4
1500mA
1400mA
1500mA
5
1800mA
1720mA
1800mA
6
2000mA
1910mA
2000mA
7
2500mA
2370mA
2500mA