![MCD Elektronik USB HUB 3.0 8-PORT Manual Download Page 21](http://html.mh-extra.com/html/mcd-elektronik/usb-hub-3-0-8-port/usb-hub-3-0-8-port_manual_1754605021.webp)
Elektronik GmbH
USB hub 3.0 8-Port
Manual
Seite 21 von 22
Command
Parameter
Return Value
Comments
with
prefix „D“
Port Functionality
A
00 – FF
ok
Connection Detection On (Sense).
X
R
A
00 – FF
Reading of the active connection detection.
X
R
AA
00 – FF
Reading of the recognition of connected devices.
C
0 – 7
0 – 3
ok
USB port to be set, mode of operation:
0 = Standard Data Port
1 = Charging Data Port (CDP) according to BC1.2
2 = Enhanced Charging Port (ECP) Multiprotocol
(Sense should be active for this function!)
3 = Dedicated Charging Port (DCP) according to
BC1.2
X
R
C
0 – 7
0 – 3
Read the operating mode (0-3, see above)
Port to read from
X
R
B
0 – 7
0 – 9
Read the currently used charger emulation.
Port to read from
L
0 – 7
0 – 7
ok
Port to set
Current Limit (see table below)
X
R
L
0 – 7
0 – 7
Reading Current Limit (see table below)
Port to read from
X
H
00 - FF
ok
Define which USB ports report to Host OS in case of a
overcurrent event.
X
R
H
00 – FF
Read reporting USB ports.
X
R
I
0 – 7
0000 – 61A8
Reading the USB port current in 0,1mA units.
Port to read from.
Behavior when switched on
SS
S | R
ok
Device status after power
S = Hub is in normal operation after being turned on
R = Hub is on standby after being turned on
Only with prefix "D"!
X
R
SS
S | R
Reading of device status after power on
X