FlowConnect FC500 Retrofit Instructions
™
FlowConnect
STEP 3: Cycle through the second menu level
The second level menu selection appear in the order
shown in the table at right.
a. Pass the wand over the
P
until you reach the
tot-S
menu selection (Figure 21).
If you pass it by, the menu selections will start
again from the beginning.
The number shown in the configuration menu
will be 00000000 and not the total gallons the
appears on the register during normal operation.
Second Menu Level
Display
Menu Title
Description
Par-S
Parent Meter Serial #
Sets Meter Serial No.
SErno
Register Serial #
Sets Register Serial No.
Set-CodE
Set Lock Code
Sets new Lock Code
GPr-dP
GPR Decimal Place
Sets GPR Decimal Place
GPr
Gallons Per Revolution
Sets GRR Digits
Smooth
Smoothing
Turns Smoothing on/off
4mA-AdJ
Trim 4mA
Adjusts 4mA Zero
20mA-AdJ
Trim 20mA
Adjusts 20mA FS
PLS-tYPE
Pulse Type
Sets Pulse Type
PLSwidth
Pulse Width
Sets Pulse Width in ms
RESEttot
Reset Total
Zeroes Total
DIS-rSt
Disable Reset Total
Permanent Reset Disable
SEE NOTE BELOW
tot-S
Set Total
Sets Total
Au-InP
Auxiliary Input
Sets operation of input
cutoff
Low Flow Cutoff
Sets Min. Flowrate
PLS-Pr
Pulses per Revolution
Sensor Pulses per rev.
L2
-Go to
Go to First Menu Level
or Run
SET
rUn
-Go to
Figure 21.
Figure 22.
Figure 23.
b. As each digit is activated, pass the wand over the
to increment to the desired number (Figure
STEP 4: Set the total
a. Pass the wand over the to move and activate
each digit (Figure 22).
Note: The flashing digits will
activate from right to left.
*
P
P
P
Do not change the setting for
the menu selection DIS-rSt!
P
EXTREMELY IMPORTANT!
Disable Reset
Total
If this is set to “YES”, you will not
be able to change or reset the
totalizer.
This will permanently change
the menus and can only be
corrected by returning the
unit to the factory to have the
firmware reflashed.
i