Preferred method of grounding
Sensor grounding for meters in
an electrically noisy environment
Sensor grounding for meters
with minimal ground noise
30122-59 Rev. 1.9 | 08APR2022
Page 6
Specifi cation Sheet
Dura Mag Flow Meter
™
D
URA
M
AG
FLOW METER SPECIFICATIONS (CONT.)
Totalizer Units
Gallons
Cubic Feet
Acre Feet
Cubic Meters
Liters
Megaliter
Metric Ton (KL)
Barrel (31G)
Barrel (42G)
Barrel (46G)
Barrel (55G)
Imperial Gallon
Acre Inch
Ton (Short)
Miners Inch Minute (11.22G)
Miners Inch Minute (9G)
Miners Inch Hour (11.22G)
Miners Inch Day (11.22G)
Miners Inch Hour (9G)
Miners Inch Day (9G)
Data Logger
• Standard with all models, minimum of fi ve years of data stored
Other Specifi cations
Options and
Accessories
• Data Logger - included as standard with fi ve years of data storage at default (12hr) interval.
(Cable sold separately)
• Bidirectional
• Epoxy coated carbon steel fl anged spool piece (for 2” & 3” wafer style meters)
• AC and DC powered with battery backup available
• Remote mount (25’ cable length only)
• Annual verifi cation / calibration
• Stainless Steel ID tag
Sensor Cable Lengths
Feet:
6, 25, 50
Meters: 1.5, 7.6, 15.25
Note: 50’ is maximum length for pulse cable.
Warranty
Meter:
5-year warranty
Battery:
5-year warranty
Liner:
Lifetime guarantee
METER GROUNDING RECOMMENDATIONS
Dura Mag meters come standard with a set of grounding rings for use with the preferred method of grounding Dura Mag
meters.
Grounding the meter body for safety according to national (NEC) or local electrical codes is recommended on ALL meter
installations. Dura Mag meters come standard with a set of grounding rings for use with the preferred method of grounding
Dura Mag meters.
See the Dura Mag IOM Manual, Lit. # 30122-53, for more information on grounding confi gurations using grounding rods
and grounding rings.
30122-53 Rev. 2.0 | 25APR2022
Page 19
Specifications
™
D
URA
M
AG