24
4.2.1 Set Adapter Type
i2cStick
i2cStick (#MIIC-207)
iPort/USB
iPort/USB (#MIIC-204)
iPort/AFM
iPort/AFM (#MIIC-203)
iPort/AI
iPort/AI (#MIIC-202)
iPort
iPort (#MIIC-201)
Variable
Variable Clock (#MIIC-201-V)
The Adapter Type argument should be the first argument in the argument list as it
controls the availability of other arguments. If the Adapter Type is not specified, the
startup adapter selection screen will be presented.
4.2.2 Set RS-232 Communication Port
1
st
Available ComPort
(Default)
COM1...COM99
Set the RS-232 communications port attached to the I
2
C adapter.
4.2.3 Set RS-232 Baud Rate
BAUD19200
(Default*)
BAUD57600
(iPort/AFM, iPort/USB, i2cStick* ONLY)
BAUD115200
(iPort/AFM, iPort/USB, i2cStick* ONLY)
Set the RS-232 Baud Rate. *i2cStick internally re-maps to 115.2K baud.
4.2.4 Set I
2
C Bus Clock Rate
CLOCK12.5K
(iPort ONLY)
CLOCK23K
(iPort/AFM, iPort/USB, i2cStick ONLY)
CLOCK86K
(iPort/AFM, iPort/USB, i2cStick ONLY)
CLOCK100K
(iPort, iPort/AI, iPort/AFM, iPort/USB, i2cStick, Default)
CLOCK400K
(iPort/AFM, iPort/USB, i2cStick ONLY)
VCLOCK=nnnHz (Variable ONLY. nnn=451...57787)
Set the I
2
C Bus Clock Rate to the specified value. The defaults rate for the Variable
Clock adapter is 451Hz. The Variable Clock adapter does not support all rates
within the specified range. The Message Center will adjust the specified rate to the