McAlpine Hussmann VLL726BL Installation And Maintenance Instructions Manual Download Page 20

Page

20

Stainless steel is used inside the cabinet to give a strong corrosion resistant finish that
maximizes the cabinets service life.

It is not rustproof,

particularly in the harsh environment of Food Display cabinets.

Chlorine and bromine, commonly used for sanitisation are highly caustic chemicals for
stainless steel and heat and humidity enhance the corrosiveness of these chemicals.
Regular cleaning is the best way to prevent corrosion and add to the service life for
your stainless steel product. The goal of your cleaning and maintenance program
should be to keep the stainless steel's protective chromium oxide layer intact. This is
what prevents corrosion

REGULAR INSPECTION

To ensure reliability of the cabinet and leak tightness of the refrigerant circuit, it is
advisable that trained personnel carry out periodic maintenance.

It is recommended that a check be made 3 months after commissioning of the
cabinet and then every 6 months.

The maintenance check should include:

Leak testing of the cabinet refrigerant circuit,

Ensuring no damage has occurred to any electrical components,

Cleaning the evaporator coil,

Particular attention should be given to the operation of any
safety devices.

Checking lift glass to ensure it has not moved in the glass clamp and
that it operates correctly (VLL726E, VLL726BL, VLL727BL).

Ensure front and end ice stops are in good order and being used
(VLL727BL)

Damage to cabinet components that need to be replaced to ensure
proper cabinet operation.

These checks will ensure the best possible performance of the cabinet over its
service life.

DISPOSAL OF THE CABINET

It is encouraged that the cabinet be refurbished if practical.
If disposal is necessary, please be aware that the foam-insulated panels incorporate
cyclo-pentane as the blowing agent and will require the cabinet to be disposed of in
accordance with local authority guidelines.

REPLACEMENT PARTS

All parts that may fail during the life of the cabinet are available from McAlpine
Hussmann.

When ordering replacement parts please quote the serial number of the
cabinet to ensure correct replacement.

Summary of Contents for VLL726BL

Page 1: ...Y CASE FACILITY VLL726E VLL726BL VLL727BL VSS726E VVS727E REFRIGERATED DISPLAY CABINETS ENHANCED MODELS INSTALLATION AND MAINTENANCE INSTRUCTIONS MAN147 1 April 2013 VLL726E VLL727BL VSS726E VVS727E V...

Page 2: ...NG THE FRONT BUMPER ADJUSTING FRONT GLASS ELECTRICAL INSTALLATION DRAIN INSTALLATION PRE START CHECK LIST CABINET OPERATION 13 LOADING LIMITS FITTINGS AND ACCESSORIES TEMPERATURE CHECKING MAINTENANCE...

Page 3: ...ance of the cabinet and higher running costs LOCATION CONDITIONS Cabinets should be sited so that external influences are minimized Situations to avoid are Air draughts from Air conditioning Ventilati...

Page 4: ...ge to some components in the cabinet RECEIVING CABINETS Cabinets will always be dispatched in good condition Always inspect the cabinet and packaged accessories for damage Note any damage on the carri...

Page 5: ...ce the next cabinet as close as possible to first cabinet and set the height of the second cabinet to roughly match the first following the procedures in steps 3 4 and 5 7 Push the cases together and...

Page 6: ...ions for the fitting of these will be supplied with each kit Contact Hussmann for kit options and instructions ATTACHING THE FRONT BUMPER IMPORTANT Bumper assembly securing screws must be fitted to al...

Page 7: ...olour panel painted panel that sits at 45 fit the bumper assembly 3 Align the bottom groove in the aluminium extrusion with the bottom tag on the plastic clips 4 Push the top of the bumper assembly on...

Page 8: ...ce once the assembly has been fitted This can be done using your fingers from below the assembly 5 Pre drill the bumper assembly aluminium extrusion at every white plastic bumper clip with a 4 5mm dri...

Page 9: ...ge 9 6 Fit hex head securing screws to every white plastic bumper clip It is advised that the screws provided are used to ensure secure fixing 7 Front colour panels can now be fitted USE SCREWS PROVID...

Page 10: ...head screwdriver Philips PH2 Square drive screw driver S2 Star drive keys Allen keys Adjustable wrench Adjusting the rear posts 1 Remove the screws on the rear work top Taking care not to damage the t...

Page 11: ...moved laterally to even out the gaps between each piece of glass 2 Lift the glass to the fully open position 3 Loosen the grub screw on the locking plates at each hinge Hinge attachment screws Locking...

Page 12: ...nsulating to prevent condensation dripping onto the floor PRE START CHECK LIST It is suggested that the following items be included but not limited to any pre start check of this cabinet All electrica...

Page 13: ...d be between 1 C and 5 C These cabinets have a load limit of 100mm above the storage surface Product shall be kept at least 20mm below the bottom of the air delivery vents Food products stored within...

Page 14: ...Page 14 VSS726E VSS726E cabinets are available with curved or straight front glass TOP OF PRODUCT 20mm BELOW AIR DELIVERY VENTS 100mm PRODUCT DEPTH PRODUCT SHALL BE 50mm BELOW PRODUCT STOP...

Page 15: ...introduced to the cabinet Ice should not be stacked more than 20mm above the Ice tray Product should be at least 20mm below the rear air delivery vents ICE LOAD LIMIT 20mm ABOVE ICE TRAY PRODUCT HEIGH...

Page 16: ...limit of 100mm above the shelves and the deck rack Food products stored within the load limits are properly refrigerated Food products stored outside the load limits may not be properly refrigerated t...

Page 17: ...ank ice against them to hold in place It is very important that the patch end ice stops are fitted They prevent condensation from forming on the outside of the cabinet VVS727E fittings and accessories...

Page 18: ...8 TEMPERATURE CHECKING The air delivery temperature in this case should be checked at least once a day The temperature should be below 1 C Checking should be done systematically and the temperature re...

Page 19: ...to dilute the liquid spill until the first opportunity for a deep clean to be carried out Cleaning instructions can be found on the rear of case IMPORTANT Always isolate the cabinet from the mains po...

Page 20: ...he maintenance check should include Leak testing of the cabinet refrigerant circuit Ensuring no damage has occurred to any electrical components Cleaning the evaporator coil Particular attention shoul...

Page 21: ...Page 21 CABINET SECTIONAL VIEW VLL726E VLL726E PEDESTAL BASE VLL726E FULL BASE...

Page 22: ...Page 22 VLL726BL VLL726BL PEDESTAL BASE VLL726BL FULL BASE...

Page 23: ...Page 23 VSS726E VSS726E PEDESTAL BASE VSS726E FULL BASE VSS726E cabinets are available with curved or straight front glass Curved glass cabinet VSS726E Straight glass cabinet VSS726B...

Page 24: ...Page 24 VVS727E VVS727E PEDESTAL VVS727E FULL BASE VVS726E cabinets are available with curved or straight front glass Curved glass cabinet VVS727E Straight glass cabinet VVS727B...

Page 25: ...Page 25 VLL727BL VLL727BL PEDESTAL BASE VLL727BL FULL BASE...

Page 26: ...Page 26 CABINET JOINING DIAGRAMS VLL726E VLL726BL and VLL727BL USE THE SAME FIXING POINTS...

Page 27: ...Page 27 VSS726E...

Page 28: ...Page 28 VVS727E...

Page 29: ...Page 29 CABINET FOOTPRINT VLL726E VSS726E Frame Base 938mm 1 5 1250mm 2 1875mm 3 2500mm 4 3750mm 6...

Page 30: ...Page 30 VLL726E VSS726E Half Pedestal Base 938mm 1 5 1250mm 2 1875mm 3 2500mm 4 3750mm 6...

Page 31: ...Page 31 VVS727E VLL727BL VLL726BL Full Base 1250mm 2 1875mm 3 2500mm 4 3750mm 6...

Page 32: ...Page 32 VVS727E VLL727BL VLL726BL Half Pedestal Base 1250mm 2 1875mm 3 2500mm 4 3750mm 6...

Page 33: ...s Glass Breakage Operating Staff Installation Technician Glass in eyes Scratches Fright Unlikely Low Do not over stress glass or hit with objects Glass replacement Service Technician Strains and sprai...

Reviews: