6.2 

Machine setup screens 

 
 
 

 

 
 
 

Figure 18 

 

 

1.  Sieves constant:

 allows you to set the sieve sensors full scale to limit the 

sensitivity that can be set by the user.  

2.  Straw walker constant:

 allows you to set the straw walker sensors full scale to 

limit the sensitivity that can be set by the user. 

3.  Return constant:

 allows you to set the recovery sensors full scale to limit the 

sensitivity that can be set by the user. 
 

Pressing the DOWN key again displays the screen below. 

 
 

 
 
 
 
 
 
 
 

 

Summary of Contents for GLM KIT

Page 1: ...INSTRUCTIONS FOR USE NO 1713 GLM OEM EN REV 3 EN O E M VERSION MANUFACTURERS GLM KIT GRAIN LOSSES MONITOR MONITORING SYSTEM FOR COMBINE HARVESTERS sieve sensors straw walker sensors recovery sensors...

Page 2: ...9 0425 754713 Fax 39 0425 741130 E mail mcstaff mcelettronica it Internet www mcelettronica it Manual code 1713GLM OEM EN Issued April 2019 Edition November 2020 MC Elettronica S r l is not obliged to...

Page 3: ...or sensitivity 14 3 4 Graphic interface description 15 3 4 1 Home screen 15 3 5 Work screen 16 3 6 Screen of sensor sensitivity 17 4 Programming 18 5 User settings 19 5 1 Speed sensor calibration 21 6...

Page 4: ...ly use the equipment After buying the Monitor read the manual carefully and refer to it any time you have doubts on how to use the equipment or when you have to carry out maintenance operations Keep t...

Page 5: ...nts lightning floods fire or other causes which do not depend on MC elettronica Repairs under warranty which must be carried out in the laboratories of our authorised centres are entirely free of char...

Page 6: ...allow the operator to adjust the sieves with precision By means of a graphical interface with histograms and buzzer it will inform the operator when losses exceed the set loss threshold in order to ac...

Page 7: ...Instructions for use GLM KIT 7 3 System installation Figure 2 3 5 Virtual Terminal dimensions 40MON 0001...

Page 8: ...Instructions for use GLM KIT 8 Figure 3 ECU GLM dimensions code 40CEN 0001...

Page 9: ...ear part of the Virtual Terminal using the supplied screws Fasten the suction bracket onto a clean flat surface Otherwise the Virtual Terminal can detach itself and fall during operations Note we reco...

Page 10: ...wheel front or rear wheel of the agricultural vehicle machine or applying a metal reference protruding by at least 7 mm Figure 5 ref C Adjust the distance between the sensor and the bolts to 2 3 mm F...

Page 11: ...by at least 7mm The distance between the sensor and its metal reference varies from 2 to 3mm The figures below show two different installation examples Figure 6 Installation of the inductive sensor D...

Page 12: ...8 When switched on during the initial phase the following screen appears showing the software version of the Virtual Terminal 1 VT SET pressing the menu key when the system is starting up displays th...

Page 13: ...orking cycle The following elements can be seen on the panel 1 ON OFF system switch on and switch off 2 Menu press it once to go to the next screen press and hold down to switch to the programming mod...

Page 14: ...e 10 1 ON OFF system switch on and switch off 2 Menu press it once to go to the next screen press and hold down to switch to the programming mode 3 UP increases the selected value 4 DOWN decreases the...

Page 15: ...f measurement selection of the type of unit of measurement to use 3 Date and time set date and hour of the system 4 Backlight display backlighting intensity adjustment 5 Buzzer volume buzzer volume ad...

Page 16: ...RPM value of the destemmer paddle if the sensor is present 5 Counter ha h Indicates the average of the hectares worked per hour if the sensor is present 6 Variable range This area allows you to displ...

Page 17: ...r paddle if the sensor is present 5 Counter ha h Indicates the average of the hectares worked per hour 6 Variable range This area allows you to display one of the parameters indicated below depending...

Page 18: ...d out 2 Machine settings the screens contained in this sub menu are protected by a password that must be entered on a screen that appears when said screens open Once the password has been entered corr...

Page 19: ...nce speed sensor is required 2 Pulses rev fan allows you to set the number of pulses rev relative to the fan sensor Set to OFF if the sensor is not present 3 Pulses rev hitter allows you to set the nu...

Page 20: ...ble to access the sensor auto calibration described in detail below Pressing the UP key when no parameter is selected allows you to view the screen 2 Working width allows you to set the width relative...

Page 21: ...ground at a distance of 100 metres from each other 2 Take the tractor to the previously marked first reference point and press the ENTER key to start measuring 3 Move forwards with the tractor to the...

Page 22: ...the number starting from the digit all the way on the left and confirming the desired value with the ENTER key The procedure must be repeated for the 4 digits that make up the password Pressing the EN...

Page 23: ...sitivity that can be set by the user 2 Straw walker constant allows you to set the straw walker sensors full scale to limit the sensitivity that can be set by the user 3 Return constant allows you to...

Page 24: ...bility of the sieves sensors 2 Straw walker Constant allows you to set the calculation stability of the straw walker sensors 3 Return Constant allows you to set the calculation stability of the recove...

Page 25: ...Instructions for use GLM KIT 25 7 Diagnostics Figure 20 1 ECU software version display of the ECU GLM software release 2 ECU voltage determines the voltage of the GLM control unit...

Page 26: ...eves mult coeff 1 100 1 50 Straw walker mult coeff 1 100 1 50 Recovery mult coeff 1 100 1 50 Type of calculation time distance time Fan rev pulses ppr 0 0 20 0 0 1 1 0 Destemmer paddle rev pulses ppr...

Page 27: ...SD for 3 5 2GB of maximum capacity Not HC not XC Formatted FAT16 not FAT32 Figure 21 2 Then insert the SD card into the housing on the left of the VT until you hear click At this point make sure that...

Page 28: ...RAPH_35 NOR wait for the loading bar to become completely yellow and the coloured bars on the side of the display will turn off ENTER you load the Eeprom setting file file SL35_VT eep wait for the loa...

Page 29: ...th the Virtual Terminal on we should be able to access the diagnostics menu as shown earlier and insert the SD card in the slot Then select Software Update to display a screen as shown in the figure 2...

Page 30: ...70 C Weather conditions Relative humidity 80 Transport and storage Temperature 25 C 70 C 11 2 ECU GLM Power supply voltage 12 Vdc Absorbed current in stand by 200 uA Maximum energy consumption 2 A Ope...

Page 31: ...5 mm Protection rating IP 67 11 3 3 Sieves straw walker recovery sensors Power supply voltage 12 Vdc Current absorption at rest 50 mA Output signal NPN 100mA Sensitivity adjustment input 1 kHz 8 Vpp D...

Page 32: ...Instructions for use GLM KIT 32 CAUTION DO NOT WASH USING A POWER WASHER WITH PRESSURE JET...

Page 33: ...Instructions for use 33 GLM KIT...

Page 34: ...Printed in Italy...

Page 35: ...Instructions for use 35 GLM KIT...

Page 36: ...Printed in Italy www mcelettronica it Electronic equipment for agriculture...