2.1
INFORMATION ON DOMINA SERIES GAS FRYERS
This booklet applies to our Domina series Fryers type A Category II (Natural Gas and L.P.G.). See table 1.1 - 2.5. The plate
according to EN 437 and EN 203 part 1
standards is under the bottom edge of the
instrument panel.
2.2
LAWS, REGULATIONS AND
TECHNICAL DIRECTIVES
TO BE OBSERVED
The following regulations must be observed
during installation:
- Current accident and fire regulations.
- The regulations of the gas supply
company, which has to issue an
authorization before installation.
- “Gas system installation” standards.
- Health regulations.
2.3
PLACE OF INSTALLATION
- The unit should be installed in a room with adequate ventilation. This unit requires a draft of at least 2 m
3
/h • kW T.C.
(Thermal Capacity).
- Install the unit in compliance with the safety regulations UNI - CIG 8723, Italian Law No. 46 dated 5-3-’90 and Ministerial
Decree No. 74 dated 12.04.96.
2.4
POSITIONING
- The various units may be installed separately or combined with other units in our range.
- This unit is not suitable for encasing.
- The distance from the side and rear walls must be at least 10 cm.; should the distance be less or the material of the walls or
floor be flammable, it is vital to install heat insulation.
2.5
TABLE II: GAS TECHNICAL DATA, PRESSURE, BURNER NOZZLES, PILOT AND MINIMUM SCREW.
UNIT TYPE: GF49T AND GF99T WITH BASIN OF 18 LITRES
R.o.A. = Regulation of primary air (1) Including the pilot thermal capacity approx. 400W.
Nozzle marking Ø 1/100
* Pressure regulator excluded K = Short nozzle l = 15 mm
F = Fixed
A = Adjustable
TA = Open all
Nation
and
category
Cat.
NOZZLE
Type
of
gas
ENG, ICEL,
DENIM, FIN,
SWED, PORT,
GREECE,
IRELAND
NETHERLANDS
ICEL,
DENMARK,
FINLAND,
SWEDEND
IRELAND
PORTUGAL
ENGLAND
GREECE
NORWAY
LUXEMBURG
LUXEMBURG
NETHERLAND
2H
2L
3B/P
3+
3P
3P
3P
G20
G25
G30*
G31
G30*
G31
G31
G31
G31
Gas pressure
upstream
mbar
Nom. Min. Max.
20
25
29
29
37
30
37
50
17
20
25
20
25
20
25
42,5
25
30
35
35
45
35
45
57,5
Ø mm. Type
MARKED
R.d.A.
X mm.
BY-PASS
Ø mm.
MARKED
PILOT
“targhet”
MARKED
165/250 K
170/350 L
115/250 K
115/250 K
120 K
115/250 K
105/250 K
32
28
TA
TA
TA
TA
TA
-
-
-
-
-
-
-
36
36
19
19
19
19
19
Gas pressure at
nozzle
with 710
Max.
mbar
Min.
mbar
Nominal
Thermal
kW (1)
100%
P.T.
Min.
Gas consumption
15°C
l/h
g/h
18,5
23,2
28,4
28,4
36,9
29,3
36,8
49,2
-
-
-
-
-
-
-
15
15
15
15
15
15
15
-
-
-
-
-
-
-
1588
1846
465
408
465
613
613
613
613
-
-
1183
1022
1183
1116
1116
1116
1116
GF49T
GF99T
l/h
g/h
3175
3693
930
816
930
1227
1227
1227
1227
-
-
2366
2044
2366
2332
2332
2332
2332
N° 3 BURNERS
V
Hz
kW
Type
tipo
Mod.
Matr.N°
Cat.
P n
IT-GR-GB-ES-IE
PT
FR-BE
NL
II2H3+
II2H3+
II2E+3+
II2L3P
20,29/37
20,29/37
20/25,29/37
25,30,50
Cat.
P n
LU
IS-DK-FI-SE
AT-CH
DE
NO
II2E3P
II2H3B/P
II2H3B/P
II2ELL3B/P
I3P
20,37,50
20,29
20,50
20,20,50
30
Qn
(Hi)
G20
G25
m
3
/h
m
3
/h
G30
G31
Kg/h
Kg/h
mbar
mbar
kW